background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C6LRE Data Sheet Set

4 of 8

Impact  

C6LRE

Dairy / Delicatessen

Electrical Data

8 ft

12 ft

Number of Fans — 9W

4   

6  

Number of Fans — 9W (Export)

4   

6  

(Export: 230V 50 hz shown)

Amperes

Watts

Merchandiser

8 ft

12 ft

8 ft

12 ft

Fans

Standard: 120V 60 hz

2.80

4.20

220

330

Energy Efficient: 120V 60 hz

1.40

2.80

112

168

Export: 230V 50 hz

1.52

2.28

228

342

Anti-sweat Heaters

Constant on

NA

NA

Cycling

NA

NA

Minimum Circuit Ampacity

With Standard Fans

3.0

4.4

With Energy Efficient Fans

1.6

3.0

With Export Fans

2.0

2.5

Maximum Over Current Protection                     20 20

Supplemental Gas Heaters

NA

NA

208V 1

Φ

Φ

Electric Defrost 

NA

NA

Standard Lighting

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Row Rail

1.02

1.54

118

170

2 Rows Canopy

1.02

1.54

118

170

2 Rows Canopy and 1 Row Rail

1.53

2.31

177

255

1 Row Ledge Lights

0.51

0.77

59

85

Optional Shelf Lighting

Not Recommended

Содержание IMPACT C6LRE

Страница 1: ...ator 0435961 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AN...

Страница 2: ...ide edge of external support 5 1 2 140 5 1 2 140 Distance between edges of external support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area...

Страница 3: ...rm F 48 Failsafe minutes 35 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control CI CO Temp F 14 4 Indoor Uni...

Страница 4: ...230V 50 hz 1 52 2 28 228 342 Anti sweat Heaters Constant on NA NA Cycling NA NA Minimum Circuit Ampacity With Standard Fans 3 0 4 4 With Energy Efficient Fans 1 6 3 0 With Export Fans 2 0 2 5 Maximum...

Страница 5: ...Blue 2 Fan Wiring Off time Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V...

Страница 6: ...opy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 5 R Standard Lighting 1 Row Canopy Optional Lighting 1 Row Rail or 1 Row Ledge Light Circuits WARN...

Страница 7: ...and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Merchandiser 23 3 4 603 Rear Coil Grilles 84 1 4 2140 37 3 4 958 73 1 8 1...

Страница 8: ...r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide both left and right D o o r s F u l l y O p e n e d R e a r C o i l G r i l l e R e a r C o i l G r i l...

Отзывы: