P/N 0443113

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

C6LRE

Refrigeration
Outlet

1

/

2

(191)

45 

1

/

2

(1156)

62 

7

/

8

(1597)

66 

5

/

8

(1693)

22

(559)

87

(2209)

3

/

4

(146)

3

/

8

 (111)

7

(178)

19

(483)

27 

1

/

2

 (699)

38 

3

/

4

 (984)

46 

5

/

8

 (1184)

29 

1

/

2

 (749)

30 

5

/

8

 (778)

35 

3

/

8

 (899)

30 

1

/

2

 (775)

3

/

4

 (70)

FAN

COIL

Impact  

C6LRE

Dairy / Delicatessen

Dimensions shown as in. & (mm).

REFRIGERATION DATA

Note: 

This data is based on store temperature

and humidity that does not exceed 75

°

F and

55% R.H. 

C6LRE

Discharge Air (°F)

32

Evaporator (°F)

21

Unit Sizing (°F)

19

Btu/hr/ft*

C6LRE

Parallel

1870

Conventional

2040

*For all refrigeration equipment other than
Hussmann, use conventional Btu values.

DEFROST DATA

C6LRE

Frequency (hr)

6

Defrost Water (lb/ft/day)

10.5

(± 15% 

based on case configuration and

product loading).

O

FF

T

IME

C6LRE

Temp Term 

(

°F)

48

°

Failsafe (minutes)

35

E

LECTRIC OR

G

AS

Not Recommended 

Standard Defrost Thermostat 

Close on rise: close 48°F  —  open 33°F 

CONVENTIONALCONTROLS

Low Pressure Backup Control
CI/CO (Temp °F)

**

14 / 4

Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**

48

°

**Use a Temperature Pressure Chart to
determine PSIG conversions.

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

2

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Estimated Charge (lb)***
8 ft 

3.2

12 ft 

4.5

***This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.

Length (in.) added to Lineup by Each 

End or Insulated Partition

1

/

2

Multideck, 6 Display Levels, and Sliding Rear Doors

NSF Certification

These merchandisers are manufactured to meet ANSI /National

Sanitation Foundation (NSF

®

) Standard #7 requirements. 

NOTE:

The bumpers are 4 in. (102 mm) wide. The center of the top bumper is

14 

1

/

8

in. (359 mm) from the floor and the center of the lower bumper

is 6 in. (152 mm) from the floor. 

Содержание IMPACT C6LRE

Страница 1: ...ator 0435961 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AN...

Страница 2: ...ide edge of external support 5 1 2 140 5 1 2 140 Distance between edges of external support and center support 40 5 8 1032 40 5 8 1032 Distance between edges of center supports NA 44 1118 Stub up area...

Страница 3: ...rm F 48 Failsafe minutes 35 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control CI CO Temp F 14 4 Indoor Uni...

Страница 4: ...230V 50 hz 1 52 2 28 228 342 Anti sweat Heaters Constant on NA NA Cycling NA NA Minimum Circuit Ampacity With Standard Fans 3 0 4 4 With Energy Efficient Fans 1 6 3 0 With Export Fans 2 0 2 5 Maximum...

Страница 5: ...Blue 2 Fan Wiring Off time Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V...

Страница 6: ...opy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 5 R Standard Lighting 1 Row Canopy Optional Lighting 1 Row Rail or 1 Row Ledge Light Circuits WARN...

Страница 7: ...and right NOTE Consult Cooler Close off Kit for instructions on connecting the merchandiser to the cooler Rear View of 8 Foot Merchandiser 23 3 4 603 Rear Coil Grilles 84 1 4 2140 37 3 4 958 73 1 8 1...

Страница 8: ...r s F u l l y O p e n e d D o o r s F u l l y C l o s e d Double walled telescoping doors slide both left and right D o o r s F u l l y O p e n e d R e a r C o i l G r i l l e R e a r C o i l G r i l...

Отзывы: