Hussmann impact C5E Скачать руководство пользователя страница 4

Electrical Data

8 Ft

12 Ft

Number of Fans — 9W

4

6

Amperes

Watts

Merchandiser

8 Ft

12 Ft

8 Ft

12 Ft

Fans

Standard (120V 60Hz)

2.80

4.20

210

330

Export (230V 50Hz)

1.52

2.28

228

342

Energy Efficient (120V 60Hz)

1.52

2.28

100

150

Constant on Anti-sweat Heaters

NA

Cycling Anti-sweat Heaters

NA

Minimum Circuit Ampacity

With Standard Fans (120V 60Hz)

3.00

4.40

Export (230V 50Hz)

1.72

2.48

With Energy Efficient Fans (120V 60Hz)

1.72

2.48

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V

15

15

Supplemental Gas Heaters

NA

208V 1

Φ

Φ

Electric Defrost

NA

Standard Lighting

1 Row Canopy

0.51

0.77

59

85

Optional Lighting

1 Row Canopy and 1 Rail

1.02

1.54

118

170

2 Row Canopy

1.02

1.54

118

170

2 Row Canopy and 1 Row Rail

1.53

2.31

177

255

1 Row Ledge Lights

0.51

0.77

59

85

Optional Shelf Lighting

1 Row of Shelves

0.51

0.77

59

85

2 Rows of Shelves

1.02

1.54

118

170

3 Rows of Shelves

1.53

2.31

177

255

4 Rows of Shelves

2.04

3.08

236

340

4 of 6

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C5E 

Data Sheet

Impact 

C5E

Meat/Delicatessen/Dairy
Precut & Packaged Produce

P

P

r

r

eliminar

eliminar

y

y

Содержание impact C5E

Страница 1: ...ng Item FAN ASSEMBLIES AND THERMOSTATS A 9W Fan Assembly 1 0047000 Fan Motor Evaporator 0380485 Fan Blade embossing toward motor B 0411744 Standard Non adjustable 2 Defrost Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace...

Страница 2: ...est knockout 88 3 8 2245 136 1 2 3467 Back of case to center of knockout 35 3 8 899 35 3 8 899 Length of electrical raceway 34 5 8 878 34 5 8 878 Waste Outlet C RH End of case to the center of waste outlet 24 1 8 613 72 1 4 1835 LH End of case to the center of waste outlet 72 1 4 1835 72 1 4 1835 Back O S of case to center of waste outlet 27 1 2 699 27 1 2 699 Water Seal Edge of water seal to cent...

Страница 3: ...ation Temp F 48 Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Drip Pipe in 1 1 2 Liquid Line in 3 8 Suction Line in 7 8 Estimated Charge lb C5E 8 ft 3 2 12 ft 4 5 This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound Length Added to Lineup by Each End or Insulated Partition in 1 1 2 P N 0407833B 3 of 6 HUSSMANN ...

Страница 4: ... 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1 Row Rail 1 53 2 31 177 255 1 Row Ledge Lights 0 51 0 77 59 85 Optional Shelf Lighting 1 Row of Shelves 0 51 0 77 59 85 2 Rows of S...

Страница 5: ...have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G S...

Страница 6: ... NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 R R R Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White 120V POWER 120V NEUTRAL WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W ...

Отзывы: