background image

4 of 8

C2-XGEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Impact  

C2-XGEP

Dairy / Delicatessen 
Precut & Packaged Produce

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—6W

1

2

2

3

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.50

1.00

1.00

1.50

39

78

78

117

120V

50Hz

Standard

0.55

1.10

1.10

1.65

42

84

84

126

230V

60Hz

Export

0.25

0.50

0.50

0.75

40

80

80

120

230V

50Hz

Export

0.28

0.56

0.56

0.84

44

88

88

132

120V

60Hz

Energy Efficient

0.26

0.52

0.52

0.78

18

36

36

54

230V

60Hz

Energy Efficient

NA

Canopy Anti-sweat Heaters

NA

0.75

0.75

1.00

45

90

90

120

Minimum Circuit Ampacity

120V

60Hz

Standard

0.70

1.95

1.95

2.70

120V

50Hz

Standard

0.75

2.05

2.05

2.85

230V

60Hz

Export

0.45

1.45

1.45

1.95

230V

50Hz

Export

0.48

1.51

1.51

2.04

120V

60Hz

Energy Efficient

0.46

1.47

1.47

1.98

230V

60Hz

Energy Efficient

NA

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Standard Lighting

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Additional 2 Row Canopy

0.51

1.02

1.02

1.54

59

118

118

170

1 Row Rail Light

0.26

0.51

0.51

0.77

30

59

59

85

1 Row Ledge Light

0.26

0.51

0.51

0.77

30

59

59

85

Optional Shelf Lighting

1 Row Shelf Receptacle

0.26

0.51

0.51

0.77

30

59

59

85

2 Row Shelf Receptacle

0.51

1.02

1.02

1.53

59

118

118

177

115V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 0.52

Содержание Impact C2-XGEP

Страница 1: ...ES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item...

Страница 2: ...2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between fr...

Страница 3: ...conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average f...

Страница 4: ...70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum...

Страница 5: ...RS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connect...

Страница 6: ...R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green...

Страница 7: ...placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less NOT...

Страница 8: ...hen facing case of the merchandiser To access the ballast 1 Remove screws from the front lip of light tray flange covering the bottom edge of the canopy Also remove screws located near the middle rear...

Отзывы: