background image

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

D

E

A

E

C

D

B

E

P/N 0457230C

Merchandisers

®

C2-XGEP

Technical Data Sheet

P/N  0457230C

NSF

®

Certified

February  2006

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

(1)

0058698

Fan Motor, Evaporator 

0142780

Fan Blade
embossing toward motor

B. 0137880

Optional Adjustable 

(2)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

H

EATERS

C.

Canopy Anti-Sweat Heater

(3)

NA

4 ft

0109417

6 ft

0109417

8 ft

0109418

12 ft

L

AMPS AND

B

ALLASTS

D.

Ballast, Electronic

(4)

0428648

2 lamps

0428649

3 lamps

0428650

4 lamps

E.

Fluorescent Lamp

(5)

Replace with like fixtures

Note: Changes are NOT underlined. 
Revision A added the canopy anti-sweat heater (pages 1,
4, 5 & 8); added 4-ft and 6-ft data (pages 1, 2, 3 & 4); and
updated wiring diagrams.
Revision B returned the correct data to page 3.
Revision C returned the correct data to page 1.

Содержание Impact C2-XGEP

Страница 1: ...ES AND THERMOSTATS A 6W Fan Assembly 1 0058698 Fan Motor Evaporator 0142780 Fan Blade embossing toward motor B 0137880 Optional Adjustable 2 Refrigeration Thermostat Item Part Description Wiring Item...

Страница 2: ...2 140 5 1 2 140 Distance between edges of external and center supports NA 31 1 8 790 40 5 8 1032 40 5 8 1032 Distance between edges of center supports 41 1 4 1048 NA NA 44 1118 Stub up area between fr...

Страница 3: ...conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Merchandiser Liquid Line in 3 8 Merchandiser Suction Line in 7 8 Estimated Charge lb 4 ft 1 6 6 ft 2 3 8 ft 3 2 12 ft 4 5 This is an average f...

Страница 4: ...70 120V 50Hz Standard 0 75 2 05 2 05 2 85 230V 60Hz Export 0 45 1 45 1 45 1 95 230V 50Hz Export 0 48 1 51 1 51 2 04 120V 60Hz Energy Efficient 0 46 1 47 1 47 1 98 230V 60Hz Energy Efficient NA Maximum...

Страница 5: ...RS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND 1 2 3 Fans 4 ft 6 ft 8 ft 12 ft Case GROUND Connector Connector G Connector Connector Connect...

Страница 6: ...R BL BL 4 BL R R BL BL 4 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R R 5 Grayed components in 12 foot models only R Red Y Yellow G Green...

Страница 7: ...placed in one of the top eight 8 locations it must comply with the angle depth requirements listed below Maximum Shelf Shelf Angle Depth 0 12 in 15 14 in or less 30 18 in or less 45 18 in or less NOT...

Страница 8: ...hen facing case of the merchandiser To access the ballast 1 Remove screws from the front lip of light tray flange covering the bottom edge of the canopy Also remove screws located near the middle rear...