background image

10

ISLA FOOD COUNTERS IM-FR / IM-FH / IM-FS  1020      

 

U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com

ENVIRONMENTAL LOCATION

These merchandisers have been designed for use 
only in air conditioned stores where temperature and 
humidity are maintained at or below 75°F and 55% 
relative humidity. DO NOT allow air conditioning, electric 
fans, ovens, open doors or windows (etc.) to create air 
currents around the merchandiser, as this will impair its 
correct operation.

UNCRATING

Place the fixture as close to its permanent position as 

possible. Remove the top of the crate. Detach the walls 
from each other and remove from the skid. Unbolt the 

case  from  the  skid. The  fixture  can  now  be  lifted  off 

the crate skid. Lift only at base of stand! (see following 
pages for details)

EXTERIOR LOADING

These models have not been structurally designed to 
support excessive external loading. Do not walk on 
their tops; This could cause serious personal injury and  

damage to the fixture.

SETTING AND JOINING

The sectional construction of these models enable them 

to be joined in line to give the effect of one continuous 

display. A joint trim kit is supplied with each joint.

It is the contractor’s responsibility to install

case(s) according to local construction and

health codes.

ATTENTION

INSTALLER

LEVELING

IMPORTANT! IT IS IMPERATIVE THAT CASES 
BE LEVELED FROM FRONT TO BACK AND SIDE 
TO SIDE PRIOR TO JOINING. A LEVEL CASE IS 
NECESSARY TO INSURE PROPER OPERATION, 

WATER DRAINAGE, GLASS ALIGNMENT AND 
OPERATION OF THE HINGES SUPPORTING THE 
GLASS. LEVELING THE CASE CORRECTLY WILL 
SOLVE MOST HINGE OPERATION PROBLEMS.

Note:   A. To avoid removing concrete flooring, begin lineup 

leveling from the highest point of the store floor.

 

B. When wedges are involved in a lineup, set them first.

TO AVOID REMOVING CONCRETE FLOORING, BEGIN 

LINEUP LEVELING FROM THE HIGHEST POINT OF 

THE STORE FLOOR.

WARNING

LEVELLING/JOINING INSTRUCTIONS

Check floor where cases are to be set to see if it’s level. 

Determine where the highest part of the floor is. Cases 

will be shimmed off this point. Using case blueprints, 

measure off and mark on floor the exact dimensions of 

the case footprint. Snap chalk line for front and back 
position of base rail. Mark location of each joint front and 

back. Use a transit to find the highest point along both 

lines. Mark the difference, and place the appropriate 

number of shims.

FLOORS ARE NOT LEVEL!!! 

  When working with two or more merchandisers 

to be joined, the whole lineup must be leveled on 
the same plane, left to right and front to back. This 
means that the entire lineup must be brought up to 
the level of the highest case in the lineup. 

Along the lines previously marked, find the highest 

point of the floor by: 

  • Walking the floor and noticing any dips or 

mounds;

 

• Using a string level; and

 

• Using a transit.

Installation (Cont’d)

Содержание IM-FH

Страница 1: ...ISLA Food Counters IM FR Refrigerated Counters IM FH Hot Counters IM FS Soup Counters P N ISLA FOOD COUNTERS 1020 INSTALLATION OPERATION GUIDE ISLA FOOD COUNTERS IM FR IM FH IM FS REV 1020...

Страница 2: ...OTICE Not related to personal injury Indicates s situations which if not avoided could result in damage to equipment The information contained in this document is the property of Hussmann Corporation...

Страница 3: ...S 20 Overhead Heating System 22 8 Maintenance 23 General Cleaning 23 Hot Well and Soup Well Cleaning 23 To Remove Lime Deposits 23 help prevent stainless steel rust 23 Plexiglass and Acrylic Care 24 C...

Страница 4: ...rrier for inspection within 15 days and retain all packaging The carrier will supply inspection report and required claim forms Shortages Check your shipment for any possible shortages of material If...

Страница 5: ...djustable Crescent Wrench This warning does not mean that Hussmann products will cause cancer or reproductive harm or is in violation of any product safety standards or requirements As clarified by th...

Страница 6: ...IONS NOTES 1 1 125 1 NOTE SOUP WELLS AND HOT WELLS USE 1 1 2 DRAIN AND 1 2 WATER LINES 2 1 125 2 NOTE AUTO FILL FOR HOT WELLS AND SOUP WELLS ARE OPTIONAL UNTIL FURTHER NOTICE 11 QT SOUP WELL DATA AMPS...

Страница 7: ...32 THEN CASE WILL BE 2 CIRCUITS WELLS AND TOP HEATERS ARE SEPARATE 4 NOTE LIGHTS ARE INCLUDED IN THE OVERHEAD HEATER DATA 2 25 1 125 AMPS WATTS HATCO GRAML 144D 240 1 PHASE HATCO HWBI 2 2 WELL 240 1 P...

Страница 8: ...0 52 56 0 20 20 N A N A N A N A N A 0 52 56 0 20 20 N A N A N A N A 10 8 5 1 15 90 0 65 70 0 25 25 N A N A N A N A N A 0 65 70 0 25 25 N A N A N A N A 12 10 6 1 38 108 0 78 84 0 29 30 N A N A N A N A...

Страница 9: ...f the crate frame releasing it from the skid 4 CAREFULLY remove slide away the remaining 3 walls and top of the crate Body panels should be on the case but if they are not carefully remove and set asi...

Страница 10: ...S IMPERATIVE THAT CASES BE LEVELED FROM FRONT TO BACK AND SIDE TO SIDE PRIOR TO JOINING A LEVEL CASE IS NECESSARY TO INSURE PROPER OPERATION WATER DRAINAGE GLASS ALIGNMENT AND OPERATION OF THE HINGES...

Страница 11: ...ody panels before lifting with a forklift Serious damage will occur if the body panels are not removed Remove the end case lower and bottom panels first Then remove the side case lower and bottom pane...

Страница 12: ...he base channels A minimum of 2 J Bars is required Place Dollies and chock wheels before lifting the other side Be sure that the dollies are evenly spaced to carry to weight of the case FLOOR JACK BOT...

Страница 13: ...and transport instructions for proper moving technique 2 Never stand on the ISLA Top Deck or any Shelves for any reason These surfaces are not steps and are not designed to support such loads Misusing...

Страница 14: ...ly designed to support excessive external loading Do not walk on their tops This could cause serious personal injury and damage to the fixture Levelling IMPORTANT It is imperative that the ISLA FOOD C...

Страница 15: ...one lubricant to help the bumper slide into the channel Step 3 Starting on one end while inserting the bumper push it up against the end cap to prevent the bumper from shrinking after installation whe...

Страница 16: ...the case to allow use of the P TRAP pipe section Never use two water seals in series in any one line Double P TRAPS in series will cause a lock and prevent draining 3 Always provide as much down hill...

Страница 17: ...aporator fans are located at the center front of these merchandisers directly beneath the display pans FOR ACCESS TO THE FANS Remove the deck pan as viewed from the front of the case ACCESS TO TX VALV...

Страница 18: ...RICAL SERVICE RECEPTACLES When Applicable The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays They are not intended nor suitable for large motors o...

Страница 19: ...Set the hot well controls to 9 and the overhead heaters to 6 Adjust as required 4 Preheat the unit for 1 hour before loading product 5 Load fully cooked heated foods only Suggested temperature for pou...

Страница 20: ...oked hot foods They are not intended to cool or reheat food Food held for prolonged periods at high temperatures will lose some of their nutritional value Food temperatures can be accurately determine...

Страница 21: ...M FS IM FH IM FR 10 20 Operation Turn power switch on Set temperature control to 7 setting Adjust as necessary Adjust overhead heater as necessary Shutting down Turn ON switch off Close fill valve Ope...

Страница 22: ...fore loading product 2 Never place food directly into the warmer Always use an inset 3 Food must be displayed in a single layer in contact with the heat source at all times 4 Using thermometer check p...

Страница 23: ...CAUSE DAMAGE OR CORROSION TO THE UNIT If your area s water has a high mineral content it may be wise to install a cartridge type filtration system to minimize buildup CLEANING EXTERIOR AREAS The EXTER...

Страница 24: ...LAENER ON ANY SURFACE DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS these will mar the finish CAUTION CLEANING GLASS AND MIRRORS Only use a soft cloth and mild glass cleaner for cleaning any glass...

Страница 25: ...aning procedures Thiswillminimizebacteriacausingdis colorationwhichleads to degraded product appearance and significantly shortening product shelf life Cleaning COLD Cases Cases with cold wells were d...

Страница 26: ...See Technical Specifications section Product load may be over its limits blocking airflow Redistribute product so it does not exceed load level There is a sticker on the inside of the case indicating...

Страница 27: ...e to case joint is missing or unsealed Install case to case joint and seal as needed Evaporator pan is overflowing if applicable Check electrical connection to evaporator pan Check float assembly it s...

Страница 28: ...Move the Power I O on off switches to the I on position Circuit breaker tripped Reset circuit breaker If issue not resolved dispatch Hatco authorized service agent Temperature Control not working prop...

Страница 29: ...defective Contact authorized Service agent or Hatco for assistance Heat is inadequate Unit mounted too high above target area Lower unit putting effective heat closer to target Excessive air movement...

Страница 30: ...zing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunde...

Страница 31: ...IM FS IM FH IM FR 10 20 To obtain warranty information or other support contact your Hussmann representative Please include the model and serial number of the product Hussmann Corporation Corporate He...

Страница 32: ...__________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ _________________...

Отзывы: