background image

January 2006

HUSSMANN - GLOVERSVILLE

             INSTALLATION & SERVICE

             INSTRUCTIONS

         FOR

               GGSM SPECIALTY MERCHANDISER

              Low Temperature

                Glass Front and Sides

P/N OII –  GGSM

January 2006

             First Call for help (US and Canada):

       1-800-922-1919

               Soporte Tècnico y Asistencia (Mèxico):

       01-800-522-1900

       For a Service Network Locator and other
                       Information visit us at

       www.hussmann.com

                           select Worldwide Locations

Содержание GGSM

Страница 1: ...MERCHANDISER Low Temperature Glass Front and Sides P N OII GGSM January 2006 First Call for help US and Canada 1 800 922 1919 Soporte T cnico y Asistencia M xico 01 800 522 1900 For a Service Network...

Страница 2: ...and Circulation 4 Glass Heaters 5 Electric Condensate Pan 5 Defrost Time Clock 5 Temperature Control 6 Temperature Control Replacement 6 Condenser 6 Defrost Stat Replacement 6 Glass Heater Wire Repla...

Страница 3: ...Loca tions where direct sunlight would shine into the cabinet for extended periods of time and locations where drafts from open doors air conditioning ducts fans and grills would blow into the cabinet...

Страница 4: ...d the lower left access panel Ac cess to the enclosure is accomplished by first removing the front access panel and then the side panel There are two screws in each end of this panel The electrical en...

Страница 5: ...rmostat built into the heater The drain car rying water to this pan should be trapped to prevent warm air migrating back to the evapo rator Defrosting of the evaporator is accom plished through the us...

Страница 6: ...cation of the cabinet in the store and store traffic should be considered when setting up this schedule TEMPERATURE CONTROL REPLACEMENT If there is product in the cabinet it must be placed in a storag...

Страница 7: ...wires Gently pull wires through hole penetration in bottom of cabinet and connect to proper terminals on ter minal board Reset timer and reassemble cabi net in reverse order BULB BALLAST REPLACEMENT...

Страница 8: ...ing 2 Relay defective 2 Replace Compressor will not start no hum 1 Power disconnected 1 Reconnect power 2 Power switch off 2 Reposition switch to ON 3 Blown or tripped breaker 3 Reset breaker 4 Defect...

Страница 9: ...ossible defrost heater joints grounded or time clock defective 5 Repair replace Low head and suction pressure 1 Short of refrigerant 1 Leak check change drier evacuate and recharge 2 Restricted cap tu...

Страница 10: ...er will not come on until the defrost thermostat temperature has been reduced below 32 F 0 C Defrost cycle too long 1 Terminating on timer failsafe factory set 40 mins 1 Replace defrost thermostat The...

Страница 11: ...ctory until such time as the defective part is returned and proved to be defective by our Quality Control De partment v Contact your Hussmann Distributor for instructions on returning in warranty part...

Страница 12: ...be given too partially offset the invoice for the replacement To obtain reimbursement forward to Hussmann Corporation 140 East State Street Gloversville NY 12078 the following information The cabinet...

Страница 13: ...IED FRACTIONAL 1 32 DECIMAL 0 031 ANGULAR 1 HOLE LOCATION SPACING 1 64 1 2 3 4 5 6 17 18 19 20 21 22 23 24 BLK 3 4 X N 2 1 S1 S3 POWER SWITCH POWER CORD COMPRESSOR CONDENSER FAN 2 R GGSM 3 DEFROST T S...

Отзывы: