background image

FWEG 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

4 of 7

Impact  

Excel

FWEG

Low / Medium Temperature

Electrical Data

Standard End

Optional

Number of Fans – 4W Evaporator

1

Equipment

Amperes

Watts

Amperes

Watts

End

End

End

End

Evaporator Fans

120V

60Hz

Standard

0.31

24

120V

50Hz

Standard

0.38

27

230V

60Hz

Export

0.15

24

230V

50Hz

Export

0.18

27

120V

60Hz

Energy Efficient

0.12

8

230V

60Hz

Energy Efficient

0.06

8

Anti-sweat Heaters (on fan circuit)

120V

50/60Hz Standard

0.65

78

230V

50/60Hz Export

0.34

78

Joining Kit Anti-sweat Heaters 

120V

50/60Hz Standard

0.40

48

230V

50/60Hz Export

0.21

48

Minimum Circuit Ampacity

120V

60Hz

Standard

1.16

1.56

120V

50Hz

Standard

1.23

1.63

230V

60Hz

Export

0.69

0.90

230V

50Hz

Export

0.72

0.93

120V

60Hz

Energy Efficient

0.97

1.37

230V

60Hz

Energy Efficient

0.60

0.81

Maximum Over Current Protection 120V

20

20

Maximum Over Current Protection 230V 

15

15

Return Glass Anti-sweat Heaters 

120V

50/60Hz Standard

0.13

16

230V

50/60Hz Export

0.07

16

208V Electric Defrost

6.54

1360

230V Export Electric Defrost

5.91

1360

120V Koolgas Defrost

1.33

160

Standard Lighting

None

Содержание FWEG

Страница 1: ...st Heaters Electric 6 0444300 End case HE 4850609 120V Drip Pan Defrost Heaters Koolgas 7 0465906 End case HE 4850628 G Nosing Anti sweat Heaters 8 0495006 End case HE 4850684 H Return Grille Anti swe...

Страница 2: ...tance between edges of external legs and center legs 48 1 2 1234 Distance between edges of center legs NA Distance between front legs and splashguard 3 1 8 82 Electrical Service Electrical Field Wirin...

Страница 3: ...Termination Not Recommended Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb End 1 5 This is an average for all refrigerant types Actual refrigerant charge may vary...

Страница 4: ...rcuit 120V 50 60Hz Standard 0 65 78 230V 50 60Hz Export 0 34 78 Joining Kit Anti sweat Heaters 120V 50 60Hz Standard 0 40 48 230V 50 60Hz Export 0 21 48 Minimum Circuit Ampacity 120V 60Hz Standard 1 1...

Страница 5: ...0 34 m3 m ARI Total Display Area 3 Sq Ft Ft 2 78 ft2 ft 0 85 m2 m Shelf Area 4 Sq Ft Ft 2 79 ft2 ft 0 85 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length...

Страница 6: ...g Unit 3 Light Blue 2 To Condensing Unit Refrigeration Thermostat Optional 1 BROWN BAND Fan BROWN BAND Nosing Anti sweat Heater 120V POWER 120V NEUTRAL 8 9 Return Grille Anti sweat Heater WARNING All...

Страница 7: ...W HUSSMANN COM Gas Defrost Optional WARNING All components must have mechanical ground and the merchandiser must be grounded Circled Numbers Parts List Item Numbers 7 4 120V Drip Pan Heater Koolgas On...

Отзывы: