REFRIGERATION DATA
Note:
This data is based on store temperature and
humidity that does not exceed 75
°
F and 55% R.H.
FL5NX-LEP
Unlit
Discharge Air (°F)
35
Evaporator (°F)
28
Unit Sizing (°F)
26
Btu/hr/ft
FL5NX-LEP
‡‡
Parallel
Conventional
U
NLIT
1350
1410
‡‡ Add 10 Btu/hr/ft
per shelf row
for LED fixtures.
Add 20 Btu/hr/ft
per shelf row
for fluorescent lamps.
DEFROST DATA
FL5NX-LEP
Frequency Hrs
8
Defrost Water (lb/ft/day)
7.0
(± 15% based on case configuration and product
loading).
O
FFTIME
FL5NX-LEP
Defrost
20
E
LECTRIC OR
G
AS
Not Recommended
CONVENTIONAL CONTROLS
Low Pressure Backup Control
CI/CO
*
FL5NX-LEP
21°F / 11°F
Indoor Unit Only, Pressure Defrost
Termination*
48°F
*Use a Temperature Pressure Chart to determine
PSIG conversions.
Estimated Charge (lb)**
FL5NX-LEP
4 ft
1.9
6 ft
2.6
8 ft
3.7
10 ft
4.4
12 ft
5.1
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
3 of 6
P/N 0474829_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
26
3
/
4
(680)
25
1
/
4
(641)
37
(940)
28
1
/
2
(724)
25
3
/
8
(644)
61
(1549)
34
5
/
8
(878)
FAN
C
O
I
L
17
1
/
4
(438)
3 In.
(77 mm)
Required
Air Gap
7
1
/
4
(183)
19
5
/
8
(499)
3
5
/
8
(92)
21
1
/
4
(540)
Refrigeration
Outlet
4
7
/
8
(123)
54
7
/
8
(1393)
4
3
/
4
(120)
Electrical
Case to Case
Connections
12
1
/
4
(311)
81
3
/
4
(2077)
Impact
Excel
FL5NX-LEP
Floral
Dimensions shown as in. and (mm).
Multi-deck, 5 Display Levels, Low Front, Narrow Footprint