Hussmann FL5NX-LEP Скачать руководство пользователя страница 3

REFRIGERATION DATA

Note: 

This data is based on store temperature and

humidity that does not exceed 75

°

F and 55% R.H. 

FL5NX-LEP

Unlit

Discharge Air (°F)

35

Evaporator (°F)

28

Unit Sizing (°F) 

26

Btu/hr/ft

FL5NX-LEP

‡‡

Parallel

Conventional

U

NLIT

1350

1410

‡‡ Add 10 Btu/hr/ft 

per shelf row

for LED fixtures.

Add 20 Btu/hr/ft 

per shelf row

for fluorescent lamps.

DEFROST DATA

FL5NX-LEP

Frequency Hrs

8

Defrost Water (lb/ft/day)

7.0

(± 15% based on case configuration and product

loading).

O

FFTIME

FL5NX-LEP

Defrost

20

E

LECTRIC OR

G

AS

Not Recommended 

CONVENTIONAL CONTROLS

Low Pressure Backup Control

CI/CO

*

FL5NX-LEP

21°F / 11°F

Indoor Unit Only, Pressure Defrost

Termination*

48°F

*Use a Temperature Pressure Chart to determine

PSIG conversions.

Estimated Charge (lb)**

FL5NX-LEP

4 ft

1.9

6 ft

2.6

8 ft

3.7

10 ft

4.4

12 ft

5.1

**This is an average for all refrigerant types.

Actual refrigerant charge may vary by

approximately half a pound.

3 of 6

P/N 0474829_C

HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

26 

3

/

(680)

25 

1

/

4   

(641)

37

 

(940)

28 

1

/

(724)

25 

3

/

8

 

(644)

61

 

(1549)

34 

5

/

8

 

(878)

FAN

L

17 

1

/

4

 

(438)

3 In. 

(77 mm) 

Required 

Air Gap

1

/

(183)

19 

5

/

8

 

(499)

5

/

8

 

(92)

21 

1

/

(540)

Refrigeration 

Outlet

7

/

8

 

(123)

54 

7

/

8

 

(1393)

3

/

(120)

Electrical 

Case to Case 

Connections

12 

1

/

4

 

(311)

81 

3

/

4

 

(2077)

Impact  

Excel

FL5NX-LEP

Floral 

Dimensions shown as in. and (mm).

Multi-deck, 5 Display Levels, Low Front, Narrow Footprint

FL5NX-LEP