Hussmann FL5NX-LEP Скачать руководство пользователя страница 2

Wireway

26 

3

/

(680)

25 

1

/

(641)

37

 

(940)

A

41 

1

/

(1054)

28 

1

/

(724)

3 In. 

(77 mm)

 

Required 

Air Gap

Refrigeration 

Outlet

Waste Outlet

Waste Outlet

FRONT

3

/

(120)

21 

1

/

(540)

D

C

8

 

(203)

12 

1

/

(307)

1

/

(108)

41 

1

/

(1054)

43 

7

/

(1114)

B

Splashguard

19

 

(483)

NOTE: Case-to-Case Electrical Connections 
are made IN FRONT OF SPLASHGUARD. 

Electrical 

Stub Up Area 

6 x 6 

(152x152)

 

Electrical 
Field 
Connection

26 

1

/

(673)

3

/

(120)

1

/

(115)

4 ft

6 ft

8 ft

10 ft

12 ft

General

(A)

Case Length 

(without ends or partitions)

48 

3

/

8

(1229)

72 

3

/

8

(1838)

96 

3

/

8

(2448)

120 

3

/

8

(3058)

144 

1

/

2

(3670)

(Each end and insulated partition adds 1 

1

/

in. (38 mm) to case line up.)

Maximum O/S dimension of case back to front 

(includes bumper)

37 (940)

37 (940)

37 (940)

37 (940)

37 (940)

Back of case to front of splashguard

28 

1

/

(724)

28 

1

/

(724)

28 

1

/

(724)

28 

1

/

(724)

28 

1

/

(724)

Back of case to O/S edge of front leg

25 

1

/

(641)

25 

1

/

(641)

25 

1

/

(641)

25 

1

/

(641)

25 

1

/

(641)

Distance between edges of external legs and center legs

NA

29 

1

/

(750)

41 

1

/

(1054)

29 

1

/

(750)

41 

1

/

(1054)

Distance between edges of center legs

NA

NA

NA

43 

7

/

(1114)

43 

7

/

(1114)

Distance between front legs and splashguard

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

3

/

4

(70)

Electrical Service             

(Electrical Field Wiring connection point)

(B)

RH End of case to center of stub up area

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

Back of case to center of stub up area

19 (483)

19 (483)

19 (483)

19 (483)

19 (483)

Length of electrical wireway

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

26 

1

/

(673)

(C)

RH End of case to LH end of wireway

42 

1

/

(1070)

66 

1

/

(1680)

90 

1

/

(2289)

114 

1

/

(2092)

138 

1

/

(3511)

Waste Outlets  

(One each end)

(D)

RH End of case to the center of LH waste outlet

36 

1

/

(921)

60 

1

/

(1530)

84 

1

/

(2140)

108 

1

/

(2750)

132 

3

/

(3363)

RH End of case to the center of RH waste outlet

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

12 

1

/

(307)

Back O/S of case to center of waste outlets

26 

3

/

(680)

26 

3

/

(680)

26 

3

/

(680)

26 

3

/

(680)

26 

3

/

(680)

Schedule 40 PVC drip pipe

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

1

/

(32)

Refrigeration Outlet

Back of case to center of refrigeration outlet

21 

1

/

(540)

21 

1

/

(540)

21 

1

/

(540)

21 

1

/

(540)

21 

1

/

(540)

RH end of case to center of refrigeration outlet

8  (203)

8  (203)

8  (203)

8  (203)

8  (203)

2 of 6

FL5NX-LEP 

Technical Data Sheet

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Engineering

Plan Views

Dimensions shown as in. and (mm).

Floral

08-2006

PHYSICAL DATA

Merchandiser Drip Pipe (in.)

1

/

4

Merchandiser Liquid Line (in.)

3

/

8

Merchandiser Suction Line (in.)

7

/

8

Wireway

Отзывы: