EcoVision EZ Door Upgrade
Acceptable Level
Bubble Range
Level Bubble
IMPORTANT! If bubble
is here, case front needs to
be shimmed up until bubble
is in center. Proper leveling
will ensure gravity close will
function throughout case
life.
Door must be opened 90°
with level placed on door
to check for gravity door
closing and hold open
function.
Do not place level on top
of door. Check level with
case filled with product.
Do not put level on top of
case.
O U T S I D E
o f D o o r
2 f t L e v e l
s h o w n
☑
x
☑
Acceptable Level
Bubble Range
20a
C.
Open door, and place level on outside of door. Repeat and check bubble level for all
doors. Level should be placed vertically as shown in the photo below. After leveling,
check that all doors close and stay closed. If not, case front needs to be shimmed up.