![Hussmann DDSS-4MC Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/hussmann/ddss-4mc/ddss-4mc_installation-and-operation-manual_2189908038.webp)
5-8
I
nstallatIon
P/N 0515957_M
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
REFRIGERATION DATA
Note:
This data is based on store temperature
and humidity that does not exceed 80
°
F
and 55% R.H. unless otherwise stated.
Schedule defrost at night while lights are
off.
DDSS-4MC
Condensing Unit (hp)
1
Condensing Unit
Capacity
9992
(Btu/hr at std. rating
conditions)
DEFROST DATA
Frequency (hr)
6
o
fftime
Failsafe (minutes)
40
Defrost Termination
Temperature
45°F (7.2°C)
PHYSICAL DATA
Refrigerant Charge
DDSS-4MC
44 oz
1.248 kg
Condensing Unit
for Optional
Self-Contained
Case
4-in. Minimum Clearance
FAN
C
O
I
L
DDSS-4MC
Dimensions shown as inches and (mm).