background image

Rev. 0508 

9

Soap and hot water are not enough to kill this bacteria. A 

sanitizing  solution  must  be  included  with  each  cleaning 

process to eliminate this bacteria.

1.   Scrub thoroughly, cleaning all surfaces, with soap 

and hot water.

2.   Rinse with hot water, but do not flood.

3.   Apply the sanitizing solution according to the 

manufacturer’s directions.

4.   Rinse thoroughly.

5.   Dry completely before resuming operation.

                          

CLEANING PRECAUTIONS

When cleaning:

• Do not use high pressure water hoses

• Do not introduce water faster than waste outlet can drain

• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN

• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL 

   BASE (these will dissolve the butyl sealants) or an AMMONIA BASE 

    (this will corrode the copper componets of the case)

TO PRESERVE THE ATTRACTIVE FINISH:

• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY

• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS  

   (these will mar the finish)

User Information (Cont'd)

Maintenance

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL

POWER AT THE MAIN DISCONNECT

WHEN SERVICING OR REPLACING ANY

ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heaters

Thermostats, and Lights.

Replacing Fluorescent Lamps

Fluorescent  lamps  are  furnished  with  a  shatterproof 

protective coating. The same type of lamp with protective 

coating must be used if replaced.

This  lamp  has  been  treated  to  resist  breakage  and  must  be
replaced  with  a  similarly  treated  lamp  in  order  to  maintain
compliance with NSF Standards.

NSF CODE 4.28.1

Contact  HUSSMANN  Chino  for  replacement

1-800-395-9229  x  2131

Replacement Lamp Part List

Refrigerated Lamps

Lamp

Q150T3/CL

J0/30V150W/79

Our Part No.

15-03-1081

15-03-1141

voltage

10VAC

0VAC

Rated Life

1500 Hrs

1500 Hrs

Manufacturer

General electric Ushio America, Inc.

Our Cost

$7.00

$.55

Telephone

1-800-554-4680

1-800-760-7446
1-800-37-0097

General Electric has many national distribution locations. 

Call for your closest location.
Ushio America Inc. is located at:
10550 Camden Drive.
Cypress, CA. 90630

T-5 Bulbs

Please note: T-5 lights must be turned off and on after bulb 

replacement.

Evaporator Fans

The evaporator fans are located at the center front of these 

merchandisers directly beneath the display pans. 

Should 

fans or blades need servicing, always replace fan blades 

with the raised embossed side of the blade TOWARD THE 

MOTOR.

Copper Coils

The copper coils used in Hussmann merchandisers may 

be repaired in the field. Materials are available from local 

refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

Содержание DBP-03

Страница 1: ...DBP DBRP 01 03 ISLAND PRODUCE p n IGIP DBP DBRP 01 03 0508 INSTALLATION OPERATION GUIDE CHINO DBP DBRP 01 03 ISLAND PRODUCE Rev 0508 Installation Operation Manual...

Страница 2: ...s Information on DBP DBRP 01 03 Island Produce Cases Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspe...

Страница 3: ...ain Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display...

Страница 4: ...ty are maintained at or below 75 F and 55 relative humidity DO NOT allow air conditioning electric fans ovens open doors or windows etc to create air currents around the merchandiser as this will impa...

Страница 5: ...and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in figure first case Apply heavy amount to cover entire shaded area DO NOT US...

Страница 6: ...means to prevent freezing The water seal should be insulated to prevent condensation Hose Reel If an optional hose reel is ordered it will be installed at the factory The water supply valve is locate...

Страница 7: ...rator outlet 2 From a refrigerant pressure temperature chart determine the saturation temperature at the observed suction pressure 3 Measure the temperature of the suction gas at the thermostatic remo...

Страница 8: ...in and around the case area free of foreign gasses and fumes or food will rapidly deteriorate 3 Maintain the display merchandisers temperature controls as outlined in the refrigerator section of this...

Страница 9: ...orescent Lamps Fluorescent lamps are furnished with a shatterproof protective coating The same type of lamp with protective coating must be used if replaced This lamp has been treated to resist breaka...

Страница 10: ...that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When contacting the factory be sure to have the Case Model and Serial Number handy This information is on...

Страница 11: ...01 CASES W0500000 CROWN CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH T...

Страница 12: ...00001 2 POINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Страница 13: ...OINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Страница 14: ...SES W0500003 8 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125...

Страница 15: ...004 10 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329...

Страница 16: ...S W0500005 12 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Страница 17: ...6 14 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Страница 18: ...07 9 OCTAGON CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01...

Страница 19: ...SSMANN CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 8 W0500008 DBRP 03 8 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 2...

Страница 20: ...N CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 32 W0500020 DBRP 03 32 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225...

Страница 21: ...HRH 561536 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230...

Страница 22: ...HRH COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230 VAC 6...

Страница 23: ...6B GE FAN 9W 4 125 01 0615A 60A CONDENSING UNIT COPELAND FJAM A150 CFV 020 225 03 7510 RLA 10 9A MCC 15 7A LRA 56 A M C R CONDENSING UNIT SAFETY SWITCH FLOAT SWITCH FISHER EVAPOWAY DM20WW 3D 2000W 240...

Страница 24: ...installer should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed...

Страница 25: ...product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mixing wi...

Страница 26: ...temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that...

Страница 27: ...___________________________ _______________ ___________________________________________________________________________________________________ _______________ ________________________________________...