background image

IGIP-DBP, DBRP 01, 03-0508

4

CL

DBP LINEUP

Modular Example

Scale = 1/8"

Crown

8'-7

3

/

4

"

5’-

9

1

/

2

"

10'-

6

3

/

4

"

3'-3

"

3'-3"

3'-10

1

/

2

"

Center Display

Mech.

stub-up

area

6"

18"

18"

18"

Mech.

Stub-up

Area

24" X 24”

24"

X

24"

4"

DBRP

Crown Section

Scale = 1/4"

26

1

/

8

"

20

1

/

8

"

10'-6

3

/

4

"

8'-1"

14

7

/

8

"

7

3

/

8

"

Straight

Racks

Optional

Step Racks

9"

4"

14

7

/

8

"

DBRP

Octagon Section

Scale = 1/4"

Straight

Racks

Optional

Step Racks

4"

26

1

/

8

"

20

1

/

8

"

15

7

/

8

"

9'-4

1

/

8

"

6'-11

1

/

2

"

15

7

/

8

"

9"

7

3

/

8

"

4"

9'-4

1

/

8

"

10

'-1

3

/

8

"

DBRP-OCTAGON

Plan View

Scale = 1/4"

Drain

Drain

Ref.

Elec.

Crown

8'-7

3

/

4

"

5'-9

1

/

2

"

10'-6

3

/

4

"

3'-3

"

3'-

3"

3'-10

1

/

2

"

DOUBLE DOG PLAN

Modular Example

Scale = 1/8"

Cut and Plan views (Cont'd)

Installation

Location

The  refrigerated  merchandisers  have  been  designed 

for use only in air conditioned stores where temperature 

and humidity are maintained at or below 75°F and 55% 

relative humidity. DO NOT allow air conditioning, electric 

fans, ovens, open doors or windows (etc.) to create air 

currents around the merchandiser, as this will impair its 

correct operation.
Product  temperature  should  always  be  maintained  at  a 

constant and proper temperature. This means that from the 

time the product is received, through storage, preparation 

and  display,  the  temperature  of  the  product  must  be 

controlled to maximize life of the product.

Uncrating the Stand

Place  the  fixture  as  close  to  its  permanent  position  as 

possible. Remove the top of the crate. Detach the walls 

from each other and remove from the skid. Unbolt the case 

from the skid. The fixture can now be lifted off the crate 

skid. 

Lift only at base of stand!

Exterior Loading

These  models  have 

not

  been  structurally  designed  to 

support excessive external loading. 

Do not walk on their 

tops;

 This could cause serious personal injury and damage 

to the fixture.

Содержание DBP-03

Страница 1: ...DBP DBRP 01 03 ISLAND PRODUCE p n IGIP DBP DBRP 01 03 0508 INSTALLATION OPERATION GUIDE CHINO DBP DBRP 01 03 ISLAND PRODUCE Rev 0508 Installation Operation Manual...

Страница 2: ...s Information on DBP DBRP 01 03 Island Produce Cases Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspe...

Страница 3: ...ain Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display...

Страница 4: ...ty are maintained at or below 75 F and 55 relative humidity DO NOT allow air conditioning electric fans ovens open doors or windows etc to create air currents around the merchandiser as this will impa...

Страница 5: ...and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in figure first case Apply heavy amount to cover entire shaded area DO NOT US...

Страница 6: ...means to prevent freezing The water seal should be insulated to prevent condensation Hose Reel If an optional hose reel is ordered it will be installed at the factory The water supply valve is locate...

Страница 7: ...rator outlet 2 From a refrigerant pressure temperature chart determine the saturation temperature at the observed suction pressure 3 Measure the temperature of the suction gas at the thermostatic remo...

Страница 8: ...in and around the case area free of foreign gasses and fumes or food will rapidly deteriorate 3 Maintain the display merchandisers temperature controls as outlined in the refrigerator section of this...

Страница 9: ...orescent Lamps Fluorescent lamps are furnished with a shatterproof protective coating The same type of lamp with protective coating must be used if replaced This lamp has been treated to resist breaka...

Страница 10: ...that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When contacting the factory be sure to have the Case Model and Serial Number handy This information is on...

Страница 11: ...01 CASES W0500000 CROWN CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH T...

Страница 12: ...00001 2 POINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Страница 13: ...OINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Страница 14: ...SES W0500003 8 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125...

Страница 15: ...004 10 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329...

Страница 16: ...S W0500005 12 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Страница 17: ...6 14 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Страница 18: ...07 9 OCTAGON CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01...

Страница 19: ...SSMANN CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 8 W0500008 DBRP 03 8 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 2...

Страница 20: ...N CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 32 W0500020 DBRP 03 32 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225...

Страница 21: ...HRH 561536 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230...

Страница 22: ...HRH COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230 VAC 6...

Страница 23: ...6B GE FAN 9W 4 125 01 0615A 60A CONDENSING UNIT COPELAND FJAM A150 CFV 020 225 03 7510 RLA 10 9A MCC 15 7A LRA 56 A M C R CONDENSING UNIT SAFETY SWITCH FLOAT SWITCH FISHER EVAPOWAY DM20WW 3D 2000W 240...

Страница 24: ...installer should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed...

Страница 25: ...product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mixing wi...

Страница 26: ...temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that...

Страница 27: ...___________________________ _______________ ___________________________________________________________________________________________________ _______________ ________________________________________...