background image

11

Installation (Cont'd)

Bumper Installation Instructions

Step 1: Make sure the aluminum channel 
and end caps are installed.

Step 2: Use silicone lubricant to help the 
bumper slide into the channel.

Step 3: Starting on one end: while inserting 
the bumper, push it up against the end cap 
to prevent   the  bumper  from  shrinking 
after installation (when it gets cold).

Step 4: As you insert the bumper into the 
channel with one hand, pull the bumper 
toward  you  with  the  other  to  open  the 
inside lips. Slowly apply pressure by rolling 
the bumper into the track.

Содержание CR3HV-ND

Страница 1: ...AND SELF SERVICE DELI CASE WITH REAR STORAGE R3HV ND B CR3HV ND B R3HV ND CR3HV ND INSTALLATION OPERATION GUIDE CHINO R3HV ND B CR3HV ND B R3HV ND CR3HV ND D REFRIGERATED HIGH VOLUME NARROW STRAIGHT O...

Страница 2: ...uncrated a claim for concealed damage is made Make request in writing to carrier for inspection within 15 days and retain all packaging The carrier will supply inspection report and required claim for...

Страница 3: ...Table of Contents 3 3 Cut and Plan Views 4 4 Installation 5 5 Plumbing 12 6 Refrigeration 13 7 Electrical 15 8 User Information 16 9 Electrical Wiring Diagrams 19 10 Wiring Diagrams 20 11 Troubleshoo...

Страница 4: ...Views SUPPORT LEGS REAR CLOSE OFF FRONT CLOSE OFF 3 7 8 7 50 1 8 21 12 1 2 17 FRONT OF CASE LENGTH VARIES 14 1 4 6 15 1 1 8 1 1 8 Drop Elect 7 32 4 4 Drop Refrig Lower Drain Upper Drain 44 56 6 8 77 5...

Страница 5: ...HERE SUPPORT IS BEST TO PREVENT DAMAGE TO THE CASE 1 It is imperative that the cases be leveled from front to back and side to side as they are being joined beginning with the rst case that is set in...

Страница 6: ...iner is not damaged Be careful to observe the area where the clamp is being tightened so that the case is not damaged as pressure is applied 8 Attach cases together via 2 bolts located in the end leg...

Страница 7: ...LASS Hex screws along glass clamp may have loosened during shipping Retighten all glass clamp screws before opening glass IMPORTANT INFORMATION Level Minitop Hardware IF GLASS DOES NOT CLOSE STAY OPEN...

Страница 8: ...f pinched at the bottom Gap is more narrow at the bottom than at the top Adjust outside hinges Center hinge stationary This diagram indicates that raising the outside hinges widens the gap at the bott...

Страница 9: ...middle hinge to the front pushes the inside edges further away from the surface or edge which the glass rests upon Which hinge s should I adjust rst In most cases the center hinge is the rst candidate...

Страница 10: ...After cases have been leveled and joined and refrigeration electrical and waste piping work completed install the splashguards and joint trim where necessary Fasten the splash guards along the top ed...

Страница 11: ...slide into the channel Step 3 Starting on one end while inserting the bumper push it up against the end cap to prevent the bumper from shrinking after installation when it gets cold Step 4 As you inse...

Страница 12: ...as part of the condensate drain to prevent air leakage or insect entrance Store plumbing system oor drains should be at least 14 off the center of the case to allow use of the P TRAP pipe section Neve...

Страница 13: ...ion valves and case controllers can be utilized Please refer to EEV and controller manufacturers information sheet Sensors for electronic expansion valves will be installed on the coil inlet coil outl...

Страница 14: ...See Spec sheets Parallel Conventional For all refrigeration equipment other than Hussmann use conventional Btu values Defrost Data See Spec Sheets Frequency Hrs OFFTIME Temp Term F Failsafe Minutes E...

Страница 15: ...ation thermostats Case amperes are listed on the wiring diagram but always check the serial plate LED Driver Location LED Drivers are located within the access panel Electrical raceway that runs the l...

Страница 16: ...Materials are available from local refrigeration wholesalers Hussmann recommends using 15 Sil Fos for repairs Aluminum Coils The aluminum coils should be replaced if damaged Non Glare Glass Optional T...

Страница 17: ...5 H 4 If front self service case is not performing check proper installation of lower deck pan refer to case cleaning section Case Cleaning Long life and satisfactory performance of any equipment are...

Страница 18: ...inated or Non chloride Containing Cleaners While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of...

Страница 19: ...19 9 Electrical Wiring Diagrams MODEL DESCRIPITION SIZE DIAGRAM R3HV ND NB R3 CR3 HV 4 R ND NB 4 3016816 R3 CR3 HV 6 R ND NB 6 3016817 R3 CR3 HV 8 R ND NB 8 3016818 R3 CR3 HV 12 R ND NB 12 3016819...

Страница 20: ...T BE GROUNDED WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED C SHEET 1 OF 2 CIRCUIT 1 L1 LOADING 1 6 120V T STAT 1 225 01 0707 TOP SECTION TAG WHITE BLACK TOP SECTION TAG BROWN HTR ELMT...

Страница 21: ...WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED C SHEET 1 OF 2 CIRCUIT 1 L1 LOADING 2 5 120V T STAT 1 225 01 0707 TOP SECTION TAG WHITE BLACK HTR ELMT 91 150W 1 39A 120V 1H36822550 TAG...

Страница 22: ...WHEN PASSING WIRES THROUGH METAL HOLES A GROMMET MUST BE USED C SHEET 1 OF 2 CIRCUIT 1 L1 LOADING 2 9 120V T STAT 1 225 01 0707 TOP SECTION TAG WHITE BLACK TOP SECTION TAG BROWN HTR ELMT 91 200W 1 85...

Страница 23: ...23 Wiring Diagrams Cont d 0 1 2 1 2 1 2 3 3 3 3 3 3 1 2 3 3 3 4 4 4 4 4 4...

Страница 24: ...locked make sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Condensing coil or evaporator coil is clogged or dirt...

Страница 25: ...e sure debris is not blocking the intake section Coil close offs are not installed Inspect coil to make sure these parts are on the case Large gap is visible on bottom of front glass or glass can t be...

Страница 26: ...eld experience over many years 1 1 The installer is responsible for following the installation instructions and recommendations provided by Hussmann for the installation of each individual type refri...

Страница 27: ...vices that are scaled only in Fahrenheit shall be accurate to 2 F The thermometer should be checked for proper calibration It should read 32 F when the stem is immersed in an ice water bath b LOCATION...

Страница 28: ...f so have the modi cations been made in accordance with the recommendations of the equipment manufacturer Is the refrigerator charged with the proper refrigerant and lubricant Does the system use the...

Страница 29: ...29 13 Spec Sheets...

Страница 30: ...ed more of a right to know law than a pure product safety law When used as designed Hussmann believes that our products are not harmful We provide the Proposition 65 warning to stay in compliance with...

Страница 31: ...____________________________________________ _______________ __________________________________________________________________________________________________ _______________ ________________________...

Отзывы: