HUSSMANN CORPORATION • BRIDGETON, MO  63044-2483 U.S.A. • WWW.HUSSMANN.COM

Impact  

Excel

C2XEC-XE

Dairy/Delicatessen

Precut & Packaged Produce

ESTIMATED SHIPPING WEIGHT 

5

Case

Solid End

4 ft

6 ft

8 ft

12 ft

(each)

lb 

(kg)

600 (272)

800 (363)

1000 (454)

1200 (544)

75 (34)

5

Actual weights will vary according to optional kits included.

Product Data

ARI Refrigerated Volume 

(Cu Ft/Ft)

4.13 ft

3

/ft  (0.38 m

3

/m)

Recommended Usable Cube 

2  

(Cu Ft/Ft)

3.85 ft

/ft  (0.36 m

/m)

ARI Total Display Area 

3  

(

Sq Ft/Ft)

3.29 ft

2

/ft  (1.00 m

/m)

Shelf Area 

4

(Sq Ft/Ft)

6.54 ft

2

/ft  (1.99 m

/m)

1

Computed using ARI 1200 standard methodology: Refrigerated Volume, ft

3

[m

3

]/Unit of Length, ft [m]

2

ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft

3

/ft [m

3

/m]

3

Computed using ARI 1200 standard methodology:  Total Display Area, ft

2

[m

2

]/Unit of Length, ft [m]

4

Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann 

Product Reference Guide

. The standard shelf complement for this model is (1) row of 12-inch shelf, 

(1) row of 14-inch shelf and (1) row of 16-inch shelf.

Содержание C2XEC-XE

Страница 1: ...n Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744...

Страница 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Страница 3: ...n 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C2XEC XE 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant...

Страница 4: ...Efficient 0 39 0 44 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V...

Страница 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 29 ft2 ft 1 00 m2 m Shelf Area 4 Sq Ft Ft 6 54 ft2 ft 1 99 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m...

Страница 6: ...wo Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 6 5 6 6 Connector W B BL BL R BL R R R Optional Lig...

Страница 7: ...echanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 6 6 6 B W 6 ft...

Страница 8: ...L R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Страница 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth...

Страница 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...

Отзывы: