background image

4 of 10

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

C2XEC-XE

Technical Data Sheet

Electrical Data

4 ft

6 ft

8 ft

12 ft

Number of Fans—7W

1

2

3

Number of Fans—4W

2

Amperes

Watts

4 ft

6 ft

8 ft

12 ft

4 ft

6 ft

8 ft

12 ft

Evaporator Fan

120V

60Hz

Standard

0.50

0.62

1.00

1.50

39

48

78

117

120V

50Hz

Standard

0.55

0.76

1.10

1.65

42

54

84

126

230V

60Hz

Export

0.25

0.30

0.50

0.75

39

48

78

117

230V

50Hz

Export

0.28

0.36

0.56

0.84

42

54

84

126

120V

60Hz

Energy Efficient

0.19

0.24

0.38

0.57

14

16

28

42

230V

60Hz

Energy Efficient

0.10

0.12

0.20

0.30

14

16

28

42

Minimum Circuit Ampacity 

120V

60Hz

Standard

0.70

0.82

1.20

1.70

120V

50Hz

Standard

0.75

0.96

1.30

1.85

230V

60Hz

Export

0.45

0.50

0.70

0.95

230V

50Hz

Export

0.48

0.56

0.76

1.04

120V

60Hz

Energy Efficient

0.39

0.44

0.58

0.77

230V

60Hz

Energy Efficient

0.30

0.32

0.40

0.50

Maximum Over Current Protection 120V

20

20

20

20

Maximum Over Current Protection 230V

15

15

15

15

Anti-sweat Heaters

120V

50/60Hz Standard

0.10

0.15

0.20

0.30

12

18

24

36

Standard Lighting (T-8 Fluorescent)

1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

Optional Lighting (T-8 Fluorescent)

Additional 1 Row Canopy

0.26

0.51

0.51

0.77

30

59

59

85

1 Row Rail Light

0.26

0.51

0.51

0.77

30

59

59

85

Optional Shelf Lighting (T-8 Fluorescent)

3 Rows of Shelves

0.77

1.53

1.53

2.31

59

177

177

255

Optional Always*Bright LED Lighting

3 Rows of Shelves

0.38

0.53

0.74

1.11

45

63

89

133

120V Lighting Circuit Total = Standard Li Total Optional Li Optional Shelf Lighting

230V Lighting Circuit Total = Multiply 120V Lighting Circuit Total by 0.52

not include Canopy A/S Heaters because heaters are wired

separately from fans.

Impact  

Excel

C2XEC-XE

Dairy/Delicatessen

Precut & Packaged Produce

Содержание C2XEC-XE

Страница 1: ...n Blade FB 4780617 4W Energy Efficient Fan Assembly 1 0477653 Fan Motor Evaporator MO 4410544 0382383 Fan Blade FB 4780617 THERMOSTATS B 0411744 Standard Non adjustable 2 Defrost Thermostat CT 0411744...

Страница 2: ...een edges of external legs and center legs NA 29 1 2 750 41 1 2 1054 41 1 2 1054 Distance between edges of center legs NA NA NA 43 7 8 1114 Distance between front legs and splashguard 2 3 4 70 2 3 4 7...

Страница 3: ...n 48 F Use a Temperature Pressure Chart to determine PSIG conversions Estimated Charge lb C2XEC XE 4 ft 1 2 6 ft 1 6 8 ft 2 3 12 ft 3 3 This is an average for all refrigerant types Actual refrigerant...

Страница 4: ...Efficient 0 39 0 44 0 58 0 77 230V 60Hz Energy Efficient 0 30 0 32 0 40 0 50 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 230V 15 15 15 15 Anti sweat Heaters 120V...

Страница 5: ...m3 m ARI Total Display Area 3 Sq Ft Ft 3 29 ft2 ft 1 00 m2 m Shelf Area 4 Sq Ft Ft 6 54 ft2 ft 1 99 m2 m 1 Computed using ARI 1200 standard methodology Refrigerated Volume ft3 m3 Unit of Length ft m...

Страница 6: ...wo Row Canopy Connector BL BL W G R BL W R R R BL BL R BL R R R B B Orange or Tan Band Standard Lighting 1 Row Canopy Optional Lighting 2 Row Canopy 6 5 6 6 Connector W B BL BL R BL R R R Optional Lig...

Страница 7: ...echanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Optional Shelf Harness and Light Circuits for Three Rows of Shelves 4 ft case 6 6 6 B W 6 ft...

Страница 8: ...L R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R BL R BL R BL R BL R BL R BL R BL 8 8 8 8 8 8 8 R BL 7 B B W W BL R R Red G Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNI...

Страница 9: ...shelves The depth of the shelf used in the top eight 8 shelf hole locations is critical to case performance If a shelf is placed in one of the top eight 8 locations it must comply with the angle depth...

Страница 10: ...ballast for the canopy and shelf lamps is located behind the canopy on the left hand end when facing case of the merchandiser To access the ballast 1 Remove screws at bottom edge of canopy and rear of...

Отзывы: