background image

The temperature control is located on the
condensing unit on the wall

, For these

merchandisers the control set at number 4
position will mantain product temparature
in a range of 36 ºF to 42 ºF (2.2 ºC to 5.5
ºC) .

The control is adjustable by runinig the
dial one number at clockwise to obtain
colder temperatures

.

Turn it

counterclockwise to obtain warmer
temparatures.

Temperature control

Lighting

Interior light and lighted sign remain on
all time. An electronic ballast is locate on
the top or on condensing unit.

Defrost Water Evaporation

External drain plumbing is not required .
Behind the cooling unit housing cover ,
there is a tray for gathering and directing
defrost water from the evaporator coil to
condensing unit area , it serves

as a

reservoir for the storage of the water until
it is evaporatored by a hot gas loop from
the compressor.

5.1 START UP / OPERATION

Electrical Supply

Wiring of the unit is

complete when it is

shipped form the factory

. The unit is

supplied with a three conductor electrical
cord wich extends from the rear of the
unit. Plug the unit into correct grounded
outlet. It is recommended

that a separate

circuit be run for each cabinet to prevent
the posibility of another appliance blowing
a fuse, causing subsequent loss of product.

Equipment

MUST

be

GROUNDED!

WARNING

Plug in Instalation

SERIES

MERCHANDISERS

MEDIUMTEMPERATURE

PB2402474A

Содержание BCH

Страница 1: ...E USING THE PRODUCT SERIES MERCHANDISERS MEDIUMTEMPERATURE I O M nstalation peretion anual Models 6 8 10 13 16 18 27 37 45 68 HUSSMANN AMERICAN By HUSSMANN CORPORATION MADE IN MEXICO BY HUSSMANN AMERICAN S DE R L De C V PB2402474A ...

Страница 2: ...3 1 REFRIGERATION SYSTEM Description 4 1 Refrigerations Parts 4 1 START UP OPERATION Electrical Supply 5 1 Temperature Control 5 1 Lighting 5 1 Defrost Water Evaporation 5 1 IMPORTANT KEEP THIS MANUAL FOR THE FUTURE REFERENCE THIS MERCHANDISER ARE CONFORMED TO THE U L Underwriters Laboratories Inc NOM Norma oficial Mexicana ANCE Asociacion Nacional de Normalizacion y Certificacion sector electrico...

Страница 3: ...ring damage make request in writing to carrier for inspection within 15 days and retain all packing The carrier will supply inspection report and required claim forms 1 1 SHIPPING DAMAGE Location These merchandisers are designed for indoor operation with a recommended operating room ambient temp of 65 ºF 18 ºC 50 RH to 90 ºF 32 ºC 65 RH Their Performance is affected by store air currents when the ...

Страница 4: ...alation After the cabinet has been leveled and is in its final position the shelves may be installed There are two differents shelves one of them is a solid shelf this must be placed on the botton next to the back Others shelves may be installed Shelf spacing is adjustable by positioning the shelf clips according to your loading requirements 2 1 CABINET PREPARATION BEFORE OPERATION Levelers shelve...

Страница 5: ...hinge Hold the top wrench firmly and lose the botton nut Torque is increased or decrease by rotating the top nut After adjustment has been made Tighten the botton nut Lamps This merchandiser does not have Lighting switch Interior lamps are eqipped with a plastic shield be sure the shield is installed properly Exterior lamp Interiorlamp 2 1 CABINET PREPARATION FOR OPERATION 3 1 DIMENSION H W D W H ...

Страница 6: ... they will work alternating day by day Clean condensing every month FIG 1 A H W D h w d BCH6 67 3 4 24 1 2 21 7 8 43 1 4 21 1 2 17 5 8 3 9 37 1 BCH8 67 3 4 24 1 2 25 3 4 43 1 4 21 1 2 21 1 2 3 11 40 1 BCH8S 60 3 4 24 1 2 28 3 4 43 1 4 21 1 2 24 1 2 3 13 03 1 BCH10 67 3 4 24 1 2 28 3 4 43 1 4 21 1 2 24 1 2 3 13 03 1 BCH13 71 1 4 29 3 8 28 3 4 46 3 4 26 3 8 24 1 2 3 17 48 1 BCH16 80 3 4 29 3 8 28 3 ...

Страница 7: ...ehind the cooling unit housing cover there is a tray for gathering and directing defrost water from the evaporator coil to condensing unit area it serves as a reservoir for the storage of the water until it is evaporatored by a hot gas loop from the compressor 5 1 START UP OPERATION Electrical Supply Wiring of the unit is complete when it is shipped form the factory The unit is supplied with a thr...

Страница 8: ...VAPORATOR FAN MOTORS MOTOR EVAPORADOR 2 OPCIONAL MOTOPROTECTOR RELAY 2 14 12 10 11 13 3 THERMIC INTERIOR LAMP EXTERIOR LAMP BALLAST BALASTRA 115 VOLTS N WARNING UNPLUG THE COOLER BEFORE DESSERVICE TO AVDID INJURIES VOLTAGE VOLTAJE 115 V FRECUENCY FRECUENIA 60 Hz MAX LEAKAGE CURRENT CORRIENTE DE FUGA 0 5 mA MAX RESISTENCE RESISTENCIA MAX 0 14 CONDITIONS STD ASHRAE ELECTRICAL SPECIFICATIONS ANTES DE...

Страница 9: ...SERIES MERCHANDISERS MEDIUMTEMPERATURE 6 1 Spare Parts 4 7 16 9 10 11 16 13 14 15 19 20 17 12 8 1 2 3 21 20 26 22 6 19 5 6 8 9 18 23 27 28 29 24 PB2402474A ...

Страница 10: ...e Flores Nuevo Leon C P 65550 Tel 52 818318 6403 Fax 52 8183186496 HUSMANN CORPORATION 1299 St Charles Rock Road Bridgeton MO63440 2483 MEXICO D F Arroz No 155 Col Santa Isabel Industrial C P 09820 Iztapalapa Mexico D F Tel 52 558503 1993 Fax 52 5585031985 ...

Отзывы: