3.1 DIMENSION

4.1 REFRIGERATION SYSTEM

Definition

All upright merchandisers

are equipped

with

a

hermetic or semi

-hermetic

compressor. The condenser is fin and tube
construction. The air is taken in the front-
down of the cabinet and discharged out by
the front down of the cabinet. (see fig. 1)

The temperature control

is located inside

the all in one unit. (see fig.1 A).

Others merchandisers with 2 doors, have
two condenser units , their function is
different than merchandisers with one
door.

They use an special system so that both
units work at the same times, only during
the first day , after that , they will work
alternating day by day.

Clean condensing every month.

FIG. 1

A

H

W

D

h

w

d

BCH6

67 3/4

24 1/2

21 7/8

43 1/4

21 1/2

17 5/8

3

9.37

1

BCH8

67 3/4

24 1/2

25 3/4

43 1/4

21 1/2

21 1/2

3

11.40

1

BCH8S

60 3/4

24 1/2

28 3/4

43 1/4

21 1/2

24 1/2

3

13.03

1

BCH10

67 3/4

24 1/2

28 3/4

43 1/4

21 1/2

24 1/2

3

13.03

1

BCH13

71 1/4

29 3/8

28 3/4

46 3/4

26 3/8

24 1/2

3

17.48

1

BCH16

80 3/4

29 3/8

28 3/4

56 1/4

26 3/8

24 1/2

4

21

1

BCH18

80 3/4

29 3/8

32 1/4

56 1/4

26 3/8

28

4

24

1

BCH27

80 3/4

32

32 1/4

56 1/4

29

28

4

26.43

1

BCH37

80 3/4

43 1/2

32 1/4

56 1/4

29

28

8

36.91

2

BCH45

80 3/4

52

32 1/4

56 1/4

29

28

8

44.66

2

BCH68

80 3/4

78 1/4

32 1/4

56 1/4

29

28

12

68.59

3

MODEL

SHELVES CAPACITY FT

(CUBIC)

DOORS

DIMENSION

EXTERIOR

INTERIOR

SERIES

MERCHANDISERS

MEDIUMTEMPERATURE

PB2402474A

Содержание BCH

Страница 1: ...E USING THE PRODUCT SERIES MERCHANDISERS MEDIUMTEMPERATURE I O M nstalation peretion anual Models 6 8 10 13 16 18 27 37 45 68 HUSSMANN AMERICAN By HUSSMANN CORPORATION MADE IN MEXICO BY HUSSMANN AMERICAN S DE R L De C V PB2402474A ...

Страница 2: ...3 1 REFRIGERATION SYSTEM Description 4 1 Refrigerations Parts 4 1 START UP OPERATION Electrical Supply 5 1 Temperature Control 5 1 Lighting 5 1 Defrost Water Evaporation 5 1 IMPORTANT KEEP THIS MANUAL FOR THE FUTURE REFERENCE THIS MERCHANDISER ARE CONFORMED TO THE U L Underwriters Laboratories Inc NOM Norma oficial Mexicana ANCE Asociacion Nacional de Normalizacion y Certificacion sector electrico...

Страница 3: ...ring damage make request in writing to carrier for inspection within 15 days and retain all packing The carrier will supply inspection report and required claim forms 1 1 SHIPPING DAMAGE Location These merchandisers are designed for indoor operation with a recommended operating room ambient temp of 65 ºF 18 ºC 50 RH to 90 ºF 32 ºC 65 RH Their Performance is affected by store air currents when the ...

Страница 4: ...alation After the cabinet has been leveled and is in its final position the shelves may be installed There are two differents shelves one of them is a solid shelf this must be placed on the botton next to the back Others shelves may be installed Shelf spacing is adjustable by positioning the shelf clips according to your loading requirements 2 1 CABINET PREPARATION BEFORE OPERATION Levelers shelve...

Страница 5: ...hinge Hold the top wrench firmly and lose the botton nut Torque is increased or decrease by rotating the top nut After adjustment has been made Tighten the botton nut Lamps This merchandiser does not have Lighting switch Interior lamps are eqipped with a plastic shield be sure the shield is installed properly Exterior lamp Interiorlamp 2 1 CABINET PREPARATION FOR OPERATION 3 1 DIMENSION H W D W H ...

Страница 6: ... they will work alternating day by day Clean condensing every month FIG 1 A H W D h w d BCH6 67 3 4 24 1 2 21 7 8 43 1 4 21 1 2 17 5 8 3 9 37 1 BCH8 67 3 4 24 1 2 25 3 4 43 1 4 21 1 2 21 1 2 3 11 40 1 BCH8S 60 3 4 24 1 2 28 3 4 43 1 4 21 1 2 24 1 2 3 13 03 1 BCH10 67 3 4 24 1 2 28 3 4 43 1 4 21 1 2 24 1 2 3 13 03 1 BCH13 71 1 4 29 3 8 28 3 4 46 3 4 26 3 8 24 1 2 3 17 48 1 BCH16 80 3 4 29 3 8 28 3 ...

Страница 7: ...ehind the cooling unit housing cover there is a tray for gathering and directing defrost water from the evaporator coil to condensing unit area it serves as a reservoir for the storage of the water until it is evaporatored by a hot gas loop from the compressor 5 1 START UP OPERATION Electrical Supply Wiring of the unit is complete when it is shipped form the factory The unit is supplied with a thr...

Страница 8: ...VAPORATOR FAN MOTORS MOTOR EVAPORADOR 2 OPCIONAL MOTOPROTECTOR RELAY 2 14 12 10 11 13 3 THERMIC INTERIOR LAMP EXTERIOR LAMP BALLAST BALASTRA 115 VOLTS N WARNING UNPLUG THE COOLER BEFORE DESSERVICE TO AVDID INJURIES VOLTAGE VOLTAJE 115 V FRECUENCY FRECUENIA 60 Hz MAX LEAKAGE CURRENT CORRIENTE DE FUGA 0 5 mA MAX RESISTENCE RESISTENCIA MAX 0 14 CONDITIONS STD ASHRAE ELECTRICAL SPECIFICATIONS ANTES DE...

Страница 9: ...SERIES MERCHANDISERS MEDIUMTEMPERATURE 6 1 Spare Parts 4 7 16 9 10 11 16 13 14 15 19 20 17 12 8 1 2 3 21 20 26 22 6 19 5 6 8 9 18 23 27 28 29 24 PB2402474A ...

Страница 10: ...e Flores Nuevo Leon C P 65550 Tel 52 818318 6403 Fax 52 8183186496 HUSMANN CORPORATION 1299 St Charles Rock Road Bridgeton MO63440 2483 MEXICO D F Arroz No 155 Col Santa Isabel Industrial C P 09820 Iztapalapa Mexico D F Tel 52 558503 1993 Fax 52 5585031985 ...

Отзывы: