Hussmann austral DO13-1 Series Скачать руководство пользователя страница 25

PRODUCT INSTALLATION MANUAL

 

                         

                                                                              DO13 SELF SERVE OLIVE 

 

_________________________________________________________________________________________________________________________                                                                                                                                                                                                                                                      
Page 24

 

                                                                                                              Hussmann

 

Appendixes

 

 

Appendix 1   

Wiring diagrams 

– 

Supplied with each case.

 

 

 

Appendix 2   

Product Engineering Datasheet 

– 

Supplied with each case.

 

 

 

Appendix 3   

Setting Table 

– 

Supplied with each case.

 

 

 

Appendix 4   

Attaching case ends 

 

Case ends are normally fitted in the factory; however, they occasionally need to be attached to a case on-site.  Use this 
procedure when an end attaches to a single case and when it is common to two cases. 
 
Ensure that correct and appropriate manual handling techniques are applied when fitting a patch end. 
 
Cases must be sealed before attaching case ends.  To seal cases, refer to sealing case joins on page 9. 

 

 
To attach a case end 
 

1.  Carefully run a knife around the inside rim of the end trim, taking care not to scratch the case end surface, and 

remove the case end membrane. 

 
2.  To assist in screwing in the Lag screws, drill a 6mm hole in the mounting positions shown, using the 10mm diameter 

fixing hole location. Ensure you do not drill completely through the End. see Fig (19) 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig (19) Drill hole locations 

(Inside Right hand End shown) 

 
 
 

FRONT OF CASE 

Fixing Holes 

Содержание austral DO13-1 Series

Страница 1: ...O13 1 SERIES SELF SERVE OLIVE INSTALLATION MANUAL IM 015 Standard remote versions The following models are covered by this Manual DO13 66 Glendenning Road Glendenning NSW 2761 PO Box 42 Doonside NSW 2...

Страница 2: ...ling the waste drain 13 Connecting power supply 14 Installing sensor probes 15 Mounting fixtures 16 Commissioning 17 Cleaning case 17 Starting up 17 Start up checks 17 Decommissioning 17 Disposal 17 O...

Страница 3: ...e system The space requirement will be instructed in Pre installation section Before installing the system make sure the power source is accessible to the cases array All the power source has to be pr...

Страница 4: ...DO13 SELF SERVE OLIVE _________________________________________________________________________________________________________________________ Page 3 Hussmann Case Services Dimensions Fig 1 Service...

Страница 5: ...and Transporting cases Case dimensions can be found in the product engineering data sheets This manual is a guide only Always refer to the latest case information available from Hussmann Customer Ser...

Страница 6: ...e up no Case sequence no within line up Example 106076 42 4 identifies this case in the 4th sequence of the line 42 for the job 106076 As well as on the packaging the case identification number appear...

Страница 7: ...sition the case allocated to this position first 3 Adjust the case height using the adjustable feet if fitted or metal shims do NOT use timber to ensure the case is level to within 1 5mm from front to...

Страница 8: ...______________________________________________ Page 7 Hussmann Fig 6 Case Levelling Fig 7 Case twisting Make sure case is level Front to Back 1 5mm Side to Side 1 5mm Make sure all adjusting feet NOT...

Страница 9: ...r leakage To seal the joins 1 Remove the shelves and racks from the end bays if necessary CAUTION Electrical cords are connected between Air Delivery Panels and Shelves on Meat and Deli cases Take car...

Страница 10: ...refer to appendix 4 attaching case ends CAUTION Do not walk or sit on cases To join the cases 1 Draw up the required case tightly against the case already in position CAUTION Case joining bolts should...

Страница 11: ...es and if required silicon seal to the floor once installation is complete and drains checked for water leaks Front Panel 1 Attached front panel and align with front skid rail refer figure 12 2 Push f...

Страница 12: ...______________________________________________________ Page 11 Hussmann Side kickplate 1 Attached side kickplate as per drawing refer figure 14 2 Adjust slot in kickplate to suit Make sure kickplate i...

Страница 13: ...an up stand The evaporator coils have been charged with dry nitrogen in the factory Fig 15 Refrigeration access holes CAUTION Do not run refrigeration lines from another compressor through a case Sinc...

Страница 14: ...s to ensure they are free of leaks 8 Dehydrate the refrigeration system using the triple evacuation method Use a vacuum pump to 1000 microns for the first two evacuations and 500 microns on the third...

Страница 15: ...to floor waste drains 3 Test for leakage by pouring water down the drain and ensure trap is primed before starting refrigeration 4 NOTE All joints to be glued with suitable adhesive Connecting Power...

Страница 16: ...cases have the probes pre fitted at the factory Probe location as per Fig 17 CAUTION Refer to relevant State or Territory legislation relating to safe working heights Probe location 1 Air off probe i...

Страница 17: ...__________________________ Page 16 Hussmann Mounting fixtures Replace racks and shelves etc as necessary to store requirements Fitting racks and shelves in manners other than configured as per the pro...

Страница 18: ...ck that all fans and lights and light RCDs if installed are working correctly 3 Check the anti sweat circuit ensuring the thermostat is set correctly If installed 4 All electrical connections are secu...

Страница 19: ...listed previously Disposal Case disposal is to be carried out by the following 1 Metal component removed and recycled 2 Remaining by commercial waste management Operation Loading Merchandise Cases sho...

Страница 20: ...ny damaged electrical components are identified during inspection isolate case power and contact service contractor Visually inspect drain strainer and drain for any debris which could result in the d...

Страница 21: ...with clean dry cloth 7 Remove the base trays wash with mild soapy water and rinse 8 Remove any foreign material from the base of the case 9 Remove all food scrap 10 Carefully flush the waste drain wi...

Страница 22: ...cluding earth continuity and insulation resistance 10 Ensure that the correct fuse rating and type is fitted for all circuits 11 Clean the evaporator coil and check it for damage 12 Ensure that there...

Страница 23: ...longer defrost duration A humid store may need more frequent defrost Case shelf arrangement has been deviated significantly from original specified setup Re do the shelf arrangement as per the origin...

Страница 24: ...service P1 P2 P3 P4 P5 P6 Sensor break down value out of range or sensor incorrectly configured Check the sensors rating condition and replace if necessary HA Room temperature exceed the highest room...

Страница 25: ...re when an end attaches to a single case and when it is common to two cases Ensure that correct and appropriate manual handling techniques are applied when fitting a patch end Cases must be sealed bef...

Страница 26: ...r the remaining holes 6 Pull up the case ends lightly against the case 7 Adjust the case so that the end fits comfortably around the canopy and the top of the case and is level from front to back with...

Страница 27: ...become pinched or crushed during the positioning of base trays shelves stock Staff must be trained in the correct procedures for setting up cases and ergonomic practices Slipping Drain may leak or bec...

Страница 28: ...pproval 45bar 652 psi Refrigerant temperature 40T70oC Room Temperature 30T70oC Phase Current 450mA Drive frequency 50Hz 150Hz Phase resistance 25 oC 36ohm 10 IP Rating IP65 Step angle 15o Linear advan...

Страница 29: ..._____ Page 28 Hussmann Appendix 8 Warranty The information in this manual is for Qualified Persons Only It is NOT an Installation Guide for NON Qualified Persons To obtain warranty information or othe...

Отзывы: