English
– 9
ASSEMBLY
Mount wall mountings and rail
There are two types of wall mounting available for the
Husqvarna WS 400 series. One, the standard wall mounting,
which is supplied on delivery, and secondly the universal
swivel wall mounting.
Use the universal wall mounting when cutting doors, cutting
flush, cutting at angles and stair cutting as well as groove
cutting. If you only require an everyday straight cut you use
the fixed mounting.
Fit the universal wall mounting for the required cutting method
(See the separate manual).
Fit the standard wall mounting as set out below:
1
Mark off the cutting line and mark off the expander bolts
holes 165 mm (6.5") from the cutting line.
2
Drill 15 mm (5/8”) holes for the M12 (1/2”) expander bolts.
3
Hang the wall mountings loosely from the expander bolts,
using M6S 12 x 70 (1/2”x2”) or similar.
4
Place the rail in the wall mountings and tighten the
compression washers.
5
Check that the rail is properly aligned with the tracks on
the wall mounts before tightening the screws.
6
Adjust the distance between the cutting line and the wall
mounting. The distance between the edge and the inner
face of the saw cut should be 89 mm (3.5"). Tighten the
expander bolts.
IMPORTANT! The Husqvarna WS 400 series may only be
used with the two wall mountings described above. Older
Husqvarna wall mountings are similar to the new standard
wall mounting, but have a longer base. This mounting must
not be used with the WS 400 series as there is a risk that
the arm catches on the base of the mounting.
IMPORTANT! Only use the connectors supplied when
purchasing the saw as older connectors are not designed
for the WS 400 series.