10 mm
(0,39 in.)
1
EN- 19
SPECIFICATIONS - OPERATION - MAINTENANCE
EN
TRANSMISSION OIL LEVEL CHECKING
By keeping the motorcycle on a flat surface and in vertical position,
remove the control screw (C), and check the level through the hole
in the screw.
Note*: Have this operation made with war
-
med-up engine.
A: Draining plug
B: Filling cap
C: levelling screw
TRANSMISSION OIL CHANGE
To completely replace the oil, unscrew the plug (A) under the
oil sump and let oil come out, then screw the plug again with its
gasket and pour fresh oil from the hole of the loading plug.
Use only the prescribed quantity and type of oil.
Note:
Have this operation made with warmed-up
engine.
A: Draining plug
COOLANT LEVEL CHECK
Check level (1) in right-hand radiator when engine is cold (place
the motorcycle so that it is perpendicular to the ground). The
coolant should be approximately 10 mm above cells.
The radiator cap is provided of two unlocking positions, the
first being for the previous pressure discharge in the cooling
system.
WARNING
Avoid removing radiator cap when engine
is hot, as coolant may spout out and cause
scalding.
NOTE
Difficulties may arise in eliminating coolant
from varnished surfaces. If this occurs, wash
off with water.