ASSEMBLING AND ADJUSTMENTS
8 – English
Connect a power source
For maximum performance, the power unit should be
connected to an earthed or grounded 3-phase socket
outlet. For more information, see the ”Technical data”
section.
In the lower region of the input voltage range there is a
reduction in available output power.
If a 3-phase electrical connection is not available, the
power unit can also be connected to a 1-phase socket
outlet. Use the supplied adapter cable for 1-phase
connection. The output at 1-phase operation is
substantially lower than at 3-phase operation. For more
information, see the ”Technical data” section.
•
Before connecting a power tool to the power take-off
of the power unit, always check that the pins in the
power tool connector are not bended or damaged.
•
During operation, fit together the covers for the cable
and the power unit to avoid dirt entering the covers
which could damage the connector.
A petrol or diesel driven generator can be used as a
power source if sufficiently powerful. See typical
generator operation cases in Technical Data. The
generator must be earthed or grounded to safeguard the
function of the power unit.
Software settings
The following settings should be made before the power
unit is commissioned. See instructions in the "Menu
system" section for additional information.
•
Set time and date. (SETTINGS>TIME & DATE)
•
Select the required display language.
(SETTINGS>SET LANGUAGE)
•
Select the required units. (SETTINGS>SET UNITS)
Before starting
Perform daily maintenance.
See instructions in the section "Maintenance".
NOTICE! A generator which on some occasion
generates an input voltage outside the voltage range
specified in the technical data can damage the power
unit.
!
WARNING! Please read the operator’s
manual carefully and make sure you
understand the instructions before using
the machine.
Wear personal protective equipment. See
instructions under the ”Personal
protective equipment” heading.
Make sure no unauthorised persons are
in the working area, otherwise there is a
risk of serious personal injury.
Check that the machine is assembled
correctly and do not show any signs of
damage.
NOTICE!
The generator
must
be earthed or grounded to
safeguard the function of the power unit.