![Husqvarna PG 680 RC Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/husqvarna/pg-680-rc/pg-680-rc_operators-manual_171568040.webp)
40 – English
TROUBLESHOOTING
Error messages , remote control
When the machine stops and displays a fault message and a fault code, a more complicated fault has occurred. If the
machine indicates error messages applicable to the traction motors or battery, the machine can only be operated
manually, contact service! For more information regarding fault codes, see the following table.
•
Faults must be rectified before a fault message can be rest with 'OK' and work can continue
•
Once the fault has been rectified and work has restarted, make sure the STOP/RUN knob on the remote control is
set to STOP (turn anticlockwise).
Fault
Code
Message on the display
Cause
0x010240
Machine battery error, contact service!
Battery connected incorrectly
0x010115
Traction overload, check that machine is not
blocked!
Traction motors are overloaded
0x010140
Traction motor error, contact service if error persists! Traction motor hall-sensors signals invalid value
0x01070F
Temperature in machine is too high!
Machine temperature is high, machine is stopped
0x01070E
Temperature in machine is too low!
Machine temperature is low, machine is stopped
0x01071F
Internal error, contact service!
Flash/fram memory could not be read
0x010740
Internal error, contact service!
VFD communication fault
0x010300
Grinding disc driver error, contact service if error
persists!
General error
0x010341
Motor overload, contact service if problem persists!
Too high motor current
0x010342
Grinding disc driver error, contact service if error
persists!
Too high DC-link voltage
0x010343
Internal error, contact service!
Sum of motor phase current is not zero.
0x010348
Grinding disc driver error, contact service if error
persists!
VFD internal error
0x010349
Input voltage is too low!
Too low DC-link voltage
Disturbances in radio communication between the
remote control and the machine.
0x01034B
Grinding disc driver error, contact service!
At least one phase without current
0x01034D
Temperature in machine is too low!
Too low VFD temperature
0x01034E
Temperature in machine is too high!
Too high VFD temperature
0x010350
Motor overload, contact service if problem persists!
Too high motor temperature
0x010356
Grinding disc driver error, contact service if error
persists!
VFD internal error
0x010359
12:45
Jan 05
OK
Machine battery error, contact service!
Code: 0x00010201
ERROR
OK
Содержание PG 680 RC
Страница 93: ...Spanish 93 LOCALIZACIÓN Y CORRECCIÓN DE AVERÍAS ...
Страница 95: ...Spanish 95 LOCALIZACIÓN Y CORRECCIÓN DE AVERÍAS Tabla de resolución de problemas del convertidor de frecuencia ...
Страница 201: ......
Страница 202: ......
Страница 203: ......