Maintenance
Before
each use
Daily
Weekly
When
suction is
low
Each 6
months or
600 h
Each 12
months or
2000 h
Do a check of the connections between
the battery and the product. Do a check
of the connection between the battery
and the battery charger.
X
Do the filter purge procedure. If the suc-
tion continues to be not sufficient, clean
the prefilter with water. Refer to
move dust particles from the prefilter
.
X
Replace the cleaned prefilter if the suc-
tion continues to be not sufficient. Refer
to
To replace the prefilter on page 21
.
X
X
Replace the HEPA filter.
X
X
Replace the dust release rubber cone.
X
Replace filter cleaning rubber parts.
X
To do a check of the control panel
1. Push and hold the On/Off button until the green LED
comes on. Refer to
Functions of the control panel on
page 17
.
2. Push and hold the On/Off button until the green LED
goes off.
To do a check of the battery charger
1. Make sure that the battery charger and the power
supply cord is not damaged. Look for cracks and
other defects. (Fig. 39)
To do a check of the battery and the
battery holder
CAUTION:
Do not clean the battery or
the battery charger with water.
1. Clean the battery and the battery holder with a soft
brush. (Fig. 40)
2. Clean the cooling slots and battery connectors.
3. Make sure that the battery is not damaged and there
are no other defects, such as cracks. (Fig. 41)
To clean the product
Operation can cause contamination on all parts of the
product and all used equipment. Thus it is necessary to
clean all parts of the product and all used equipment
fully and carefully.
WARNING:
Disconnect the product
from the power supply.
WARNING:
Clean the product before
it is moved from the work area. Remaining
dust on the product can go into the air and
cause a health risk.
• Use personal protective equipment. Refer to
Personal protective equipment on page 14
.
• Do not clean the product with a high-pressure
washer or compressed air.
• Clean the external surface with a moist cloth.
• Do not use water on electrical components.
• Clean the filters as given in
page 21
.
• After servicing, put discarded parts in plastic bags.
Refer to local regulations for the correct procedure.
• If you use water to clean the product, remove the
prefilter and the Longopac before you clean. Also
make sure that no water goes into the HEPA filter.
To clean the prefilter with water
CAUTION:
Do not use a high-pressure
washer or compressed air to clean the
prefilter. Do not hit the prefilter with force to
clean it.
20
1618 - 004 - 24.01.2022
Содержание DE 110i
Страница 2: ...10 13 21 12 14 15 23 20 26 9 4 8 5 7 6 22 16 17 18 19 11 27 24 2 1 3 25 1 2 3 4 5 6 7 8 9 10 ...
Страница 4: ...19 A B C D 20 21 1 2 3 4 6 7 5 22 38 11 2 42 12 3 51 2 63 21 2 76 3 23 24 25 26 ...
Страница 5: ...27 A B A 28 29 30 X 3 5 31 A B 32 A B 33 34 ...
Страница 6: ...35 36 A B 37 38 39 40 41 A B 42 ...
Страница 7: ...43 44 45 A B C 46 47 48 49 50 ...
Страница 8: ...51 52 53 ...
Страница 101: ...1618 004 24 01 2022 101 ...
Страница 102: ...102 1618 004 24 01 2022 ...
Страница 103: ...1618 004 24 01 2022 103 ...