22. Install the drive belt cover (E) and the cover (D).
E
D
23. Set the switch for direction of rotation of the control
panel to clockwise (CW).
WARNING:
Do not use
counterclockwise direction of rotation when
you use the product as a scarifier.
Troubleshooting
Problem
Cause
Solution
Too much vibra-
tion and/or unusual
noises.
The tools are worn or damaged.
Replace parts that are worn or damaged.
The bearing is defective.
Do a check of the bearing on the axle drive
shaft and replace if it is necessary.
Incorrect tension of the drive belt.
Do a check of the drive belt tension. Refer
to
To do a check of the drive belt tension on
page 22
.
The motor is defective.
Replace the motor.
The tool drum is set to too much operation
depth.
Decrease the operation depth.
Decreased or no per-
formance.
The tools are worn or damaged.
Replace the worn parts.
The type of tools is incorrect for the surface.
Replace the tools with correct tools for the
surface.
30