16 Troubleshooting
Starter rope
does not retract
Start rope stuck
No
resistance
when pulling
the rope
Impossible to
activate choke/
stop switch
Defect
starter housing
Perform “Cleaning and in-
spection” of starter housing
(see separate instr.)
Sticking starter
housing
Defect hook/pawl
in starter housing
Stop lever/start
switch
incorrect mounted
Engine will not
rotate
Flywheel is loose
Choke valve
incorrect position
Change part or com-
plete starter if needed.
Defect starter housing
Check air gap between fly-
wheel and ignition module
Change part or com-
plete starter if needed.
Check main bearings
Check cylinder and piston
Change part if needed.
Change part if needed.
Change part if needed.
Piston ring is stuck
Perform “Cleaning and in-
spection” of starter housing
(see separate instr.)
Check the key on flywheel
and make sure that the
flywheel is tightened with the
correct torque
Check piston ring function
Change part if needed.
Tighten/change if
needed.
Change part if needed.
Check installation of stop
lever/start switch
Check position of choke valve
Correct if needed
Correct choke valve/
replace
carburettor