Troubleshooting schedule
K
eypad
Troubleshooting takes place from the keypad.
Battery and battery charger
Troubleshooting the battery and/or the battery charger during charging.
K
eypad
Possible faults
Possible action
Warning indicator flashing.
No.
3
in figure (
5
).
Overload.
The cutting attachment is jamed.
Release the cutting attachment.
Temperature deviation.
Allow the machine to cool down.
The machine does not start
The power trigger and the activate
button are pressed at the same time.
Release the power trigger and the
machine is active.
Warning indicator lit.
No.
3
in figure (
5
).
Service
Contact your service agent.
L
ED display
Possible faults
Possible action
Red LED blinking
No.
2
in figure (
26
).
The battery is discharged.
Charge the battery.
Temperature deviation.
Use the battery in surroundings
where temperatures are between -
10
°
C (
14
°
F) and
40
°
C (
104
°
F).
Over voltage.
Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.
Remove the battery from the
battery charger.
Red LED on
No.
2
in figure (
26
).
Cell difference too much (
1
V).
Contact your service agent.