10- ENG
D29728
IMPORTANT:
The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2.
Make sure the outlet being used
has the same configuration as
the grounded plug.
DO NOT
USE AN ADAPTER.
See
illustration.
3.
Inspect the plug and cord before
each use. Do not use if there are
signs of damage.
4.
If these grounding instructions
are not completely understood,
or if in doubt as to whether the
compressor is properly
grounded, have the installation
checked by a qualified
electrician.
Risk of Electrical
Shock. IMPROPER
GROUNDING CAN RESULT IN
ELECTRICAL SHOCK.
Do not modify the plug provided. If
it does not fit the available outlet, a
correct outlet should be installed
by a qualified electrician.
Repairs to the cord set or plug
MUST be made by a qualified
electrician.
Grounding Pin
Grounded
Outlets
Plug
INSTALLATION
GROUNDING INSTRUCTIONS
Risk of Electrical
Shock. In the event
of a short circuit, grounding
reduces the risk of shock by
providing an escape wire for the
electric current. This air
compressor must be properly
grounded.
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations). The plug must be used
with an outlet that has been installed
and grounded in accordance with all
local codes and ordinances.
1.
The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
HOW TO SET UP YOUR
UNIT
Location of the Air Compressor
Locate the air compressor in a clean,
dry and well ventilated area. The air
compressor should be located at
least 12" away from the wall or other
obstructions that will restrict the flow
of air. The air compressor pump and
shroud are designed to allow for
proper cooling. The ventilation
openings on the compressor are
necessary to maintain proper
operating temperature. Do not place
rags or other containers on or near
these openings.
Содержание Y1000
Страница 19: ...19 ENG D29728 NOTES...