background image

Operating The Tool

(Continued)

3. After adding oil, run

tool briefly. Wipe off
any excess oil from
the cap exhaust.

RECOMMENDED HOOKUP

The illustration below shows the
recommended hookup for the tool.

1. The air com-

pressor must
be able to
maintain a
minimum of 
60 psi when
the tool is being used. An inade-
quate air supply can cause a loss of
power and inconsistent driving.

2. An oiler can be used

to provide oil circula-
tion through the tool.
A  filter can be used
to remove liquid and
solid impurities which
can rust or “gum up”  internal parts
of the tool. 

3. Use 3/8” air

hoses with a
minimum
working pres-
sure of 150
psi. Use 1/2” air hoses for 50’ run or
longer. For better performance,
install a 3/8” quick plug  (1/4” NPT
threads) with an inside diameter of
.315" (8mm) on the tool and a 3/8”
quick coupler on the air hose.

4. Use a pressure

regulator on the
compressor, with
an operating
pressure of 0 -125
psi. A pressure regulator is required
to control the operating pressure of
the tool between 60 and 100 psi. 

SINGLE SEQUENTIAL MODE

This mode
requires the trig-
ger to be pulled
each time a fas-
tener is driven. The tool can be actuat-
ed by depressing the WCE against the

Cómo usar la
Herramienta (Cont.)

PARA CARGAR Y DESCARGAR LA
HERRAMIENTA

1. Siempre 

conecte

la herramienta a

la fuente de suminsitro de aire

antes

de colocarle los sujetadores.

2. Empuje hacia

abajo sobre
el boton del
seguro.
Mueva la
tapa del car-
gador hacia
atrás.

3a. Para puntillas,

inserte una tira
de puntillas en el
cargador.
Cerciórese de que
los extremos puntiagudos de los
clavos estén hacia la parte inferior
del cargador. Cerciórese de que los
clavos no estén sucios ni dañados.

3b. Para grapas, cargue una tira de gra-

pas con las coronas montadas sobre
el riel del cargador.

4. Empuje la tapa

del cargador
hacia delante
hasta que el
botón del
seguro salte
hacia arriba.

5. Siempre descargue el sujetador

antes de remover la herramienta de
servicio. La descarga es lo opuesto a
la carga, excepto que debe

desconectar

el suministro de aire

antes de realizar la descarga.

PARA AJUSTAR LA PENETRACION DE
LOS SUJETADORES

La HDN104 viene equipada con un
mecanismo clavador de profundidad
ajustable. Esto le permite al usuario
determinar a qué profundidad se va a
clavar en la superficie de trabajo.

1. Ajuste la presión de operación a 

aquella que usará con regularidad
para clavar los sujetadores. No exceda
la presión de 6,90 bar.

2. Para dirigir la herramienta, gire la

rueda (C) hacia la derecha hasta el
punto deseado.

3. Para clavar el sujetador más profun-

do, gire la rueda (C) hacia la izquier-
da hasta el punto deseado.

4. Asegúrese que el

gatillo y el Elemento
de Contacto de
Trabajo se mueven
libremente hacia
arriba y hacia abajo sin atascarse o
pegarse después de cada ajuste.

PARA AJUSTAR LA DIRECCION DEL

TUBO DE ESCAPE

El modelo
HDN104 está
equipado con un
deflector
ajustable de la
dirección del tubo
de escape. Éste le permite al usuario
cambiar la dirección del tubo de
escape. Simplemente mueva el deflec-
tor hacia la dirección deseada.

QUÉ HACER CUANDO LA HERRA-
MIENTA TENGA UN SUJETADOR
ATASCADO

1. Desconecte la

clavadora de
la fuente de
suministro de
aire.

2. Remuezva

todos los clavos
del depósito
(vea “Carga/
Descarga de la
Clavadora”).

Si no se 

retiran

todos los sujetadores éstos saldrán por el
frente de la herramienta.

3. Destrabe el

seguro halando
hacia afuera y
abajo. El seguro
de alambre se
destraba de los
ganchos de la boquilla.

4. Ahora se puede

girar la puerta,
dejando al
descubierto el
sujetador que
esté trabado.

5. Retire todos los

sujetadores que
estén trabados,
utilizando unas
pinzas o un
destornillador si
fuera necesario.

6

Vuelva a girar
la puerta a su
posición de
cerrado.

7. Extienda el

seguro de
alambre
y colóquelo
sobre los
ganchos de
la boquilla.

8. Cierre el seguro

empujándolo
hacia arriba y
adentro hasta
que quede a
presión en su
lugar.

!

ADVERTENCIA

Modelo HDN104

21 Sp

Manual de Instrucciones

position. The tool 

MUST NOT

OPERATE

. Do not use the tool if it

operates while lifted from the work
surface. Personal injury may result.

7. Pull the trig-

ger and
depress the
work contact
element
(WCE) against the work surface. The
tool 

MUST NOT OPERATE

.

8. Depress the

Work Contact
Element
(WCE) against
the work sur-
face. Pull the trigger. The tool

MUST OPERATE

.

An improperly
functioning tool

must not be used. Do not actuate the
tool unless the tool is placed firmly
against the work piece.

LOADING/UNLOADING THE TOOL

1. Always 

connect

the tool to the air

supply 

before

loading fasteners.

2. Push down

on the latch
button.  Pull
back on the
magazine
cover.

3a. For nails, insert a

stick into the
magazine.  Make
sure the pointed
ends of the fas-
teners are resting on the bottom
ledge of the magazine when load-
ing.  Make sure the nails are not
dirty or damaged.

3b. For staples, load a clip of staples

with the crowns straddling the mag-
azine rail.

!

WARNING

work surface followed by pulling the
trigger. 

The trigger must be released to reset
the tool before another fastener can be
driven.

CHECKING THE WORK CONTACT
ELEMENT (WCE)

Check the opera-
tion of the Work

Contact Element (WCE) trip mechanism
before each use. The WCE must move
freely without binding through its
entire travel distance. The WCE spring
must return the WCE to its fully extend-
ed position after being depressed. Do
not operate the tool if the WCE trip
mechanism is not operating properly.
Personal injury may occur.

1. Disconnect the

air supply from
the tool.

2. Remove all fas-

teners from the
magazine (see
Loading/
Unloading).

3. Make sure the trig-

ger and work con-
tact element (WCE)
move freely up and
down without stick-
ing or binding.

4. Reconnect air

supply to the
tool.

5. Depress the Work

Contact Element
(WCE) against the
work surface with-
out pulling the trig-
ger. The tool 

MUST

NOT OPERATE

. Do not use the tool

if it operates without pulling the
trigger. Personal injury may result.

6. Remove the tool

from the work sur-
face. The Work
Contact Element
(WCE) must return to
its original down

!

CAUTION

Model HDN104

Operating Instructions

4

150 PSI WP

3/8” I.D.

60 psi
Min.

100 psi
Max.

Carril del cargador

Botón del

seguro

movement

1

2

1

2

Latch
Button

Magazine rail

Gire

(C)

movemiento

Содержание HDN104

Страница 1: ...0 3 QUIEN RECIBE ESTA GARANTIA EL COMPRADOR El comprador original que no sea un revendedor del producto Campbell Hausfeld 4 PRODUCTOS CUBIERTOS POR ESTA GARANTIA Cualquier clavadora grapadora herramienta neumática pistola pulver izadora inflador o accesorio neumático suministrado o fabricado por el Garante 5 COBERTURA DE LA GARANTIA Los defectos substanciales de material y fabricación que ocurran ...

Страница 2: ...gases including but not lim ited to oxygen and combustible gases as a power source Use filtered lubricated regulated compressed air only Use of a reactive gas instead of com pressed air may cause the tool to explode which will cause death or serious personal injury Use only a pressure regulated compressed air source to limit the air pressure supplied to the tool The regu lated pressure must not ex...

Страница 3: ...ed MAY result in minor or moderate injury Do not make any modifications to the tool without first obtaining written CAUTION Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contact your air compressor manufacturer for information Operating The Tool LUBRICATION This tool requires lubrication before using the tool for the first time and before each use If an inline oiler is...

Страница 4: ...ente mueva el deflec tor hacia la dirección deseada QUÉ HACER CUANDO LA HERRA MIENTA TENGA UN SUJETADOR ATASCADO 1 Desconecte la clavadora de la fuente de suministro de aire 2 Remuezva todos los clavos del depósito vea Carga Descarga de la Clavadora Si no se retiran todos los sujetadores éstos saldrán por el frente de la herramienta 3 Destrabe el seguro halando hacia afuera y abajo El seguro de al...

Страница 5: ... fasten ers are driven consistently Do not exceed 100 psi 2 For shallow penetration turn the wheel C to right to the extent desired 3 For deeper penetration turn the wheel C to left to the extent desired 4 Make sure trigger and work contact element WCE move freely up and down without bind ing or sticking after each adjust ment ADJUSTING THE DIRECTION OF THE EXHAUST The HDN104 is equipped with an a...

Страница 6: ...y estándares para compresores de aire industriales Contacte al fabricante de su compresor de aire para mayor información Cómo usar la Herramienta LUBRICACION Esta herramienta requiere lubricación antes de usarse por primera vez y antes de cada uso Si utiliza un lubricador incorporado a la línea no tendrá que lubricarla manualmente a diario AVISO No opere la herramienta ni permita que otros la oper...

Страница 7: ...empre ajuste la herramienta con un conector o acoplador de mangueras colocado en o cerca de la her ramienta de un modo tal que se descargue todo el aire comprimido en la herramienta en el momento en que se desconecte el conector o acoplador No use una válvula de chequeo o ninguna conexión que permita que el aire pemanezca en la herramienta Se puede producir la muerte o lesiones personales graves A...

Страница 8: ...debajo de la cubierta de la boquilla y regístrelo debajo Modelo Nº ____________________ Código de fecha ___________ Conserve estos números para referencia Limited Warranty Husky 2 in 1 Nailer Stapler by Campbell Hausfeld 1 DURATION From the date of purchase by the original purchaser as follows One 1 Year 2 WHO GIVES THIS WARRANTY WARRANTOR Campbell Hausfeld Scott Fetzer Company 100 Production Driv...

Страница 9: ...ld 1 DURÉE De la date d achat par l acheteur original comme suit un 1 an 2 GARANTIE ACCORDÉE PAR GARANT Campbell Hausfeld Scott Fetzer Company 100 Production Drive Harrison Ohio 45030 Téléphone 800 543 6400 3 BÉNÉFICIAIRE DE CETTE GARANTIE ACHETEUR L acheteur original sauf en cas de revente du produit Campbell Hausfeld 4 PRODUITS COUVERTS PAR CETTE GARANTIE Tous les outils de fixation cloueuses et...

Страница 10: ...primé pourrait faire exploser l outil ce qui pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprimé à pression pour limiter la pression d air fournie à l outil La pression contrôlée ne doit pas dépasser 689 5 kPa S il y a une défaillance du régulateur la pression livrée à l outil ne doit pas dépasser 1 379 kPa L outil pourrait exploser ce qui pourrait me...

Страница 11: ...util Nettoyer et vérifier tous les tuyaux et raccords avant de brancher l outil au compresseur d air Remplacer les tuyaux ou les raccords endommagés ou usés sinon le rendement et la durabilité de l outil seront affectés Le compresseur d air utilisé avec cet outil doit conformer aux exigences établies par l American National Standards Institute Standard B19 3 1981 Safety Standard for Compressors fo...

Страница 12: ...util est muni d un réglage de péné tration Ceci permet de déterminer à quelle profondeur les attaches doivent être enfoncés 1 Régler la pression de fonction nement de manière à ce que la force d éjection des attaches soit constante Ne pas dépasser la pres sion de fonctionnement maximum de 690 kPa 2 Pour faire pénétrer une attache moins profondément tourner la roue C vers la droite jusqu à la profo...