17
HUSKYTOOLS.COM
Contact 1-888-43-HUSKY for further assistance.
Troubleshooting (continued)
Problem
Possible Cause
Solution
The air receiver pressure
drops when the compressor
shuts off.
□
The connections are loose or
leaking (fittings, tubing, etc.).
□
Check all the connections with soapy water and
look for bubbles. Thread sealing tape should be
used on all threaded connections. Tighten any
loose connections until the leak stops.
□
The drain valve is loose.
□
Tighten the drain valve.
□
The check valve is leaking.
□
Take the compressor to a authorized service
center.
DANGER:
Do not disassemble the check
valve while air is in tank - empty the all
the air out of the tank before disassembly.
There is excessive moisture in
the air discharge.
□
There is excessive water in the air
tank.
□
Drain the tank to remove water.
□
The humidity is high.
□
Move the compressor to an area of less humidity
or use an air line filter to reduce moisture
discharge in the tank.
Air is leaking from the
compressor.
□
The hose connection is loose or
improperly sealed.
□
Ensure connections are sealed with thread
sealing tape and tightened.
□
The air hose is broken or
damaged.
□
Replace the air hose.
The compressor runs
continuously.
□
The tank drain valve is open.
□
Ensure the tank drain valve is closed.
□
The pressure switch is defective.
□
Take the compressor to an authorized service
center.
□
The usage is excessive.
□
Decrease the amount of tool run-time; the
compressor is not large enough to supply the air
requirement of the tool.
The compressor vibrates.
□
The compressor mounting bolts
are loose.
□
Tighten any loose bolts on the compressor mount.
The air output is lower than
normal.
□
The inlet valves are broken.
□
Take the compressor to an authorized service
center.
□
The connections are leaking.
□
Apply thread sealing tape to threaded connections
and tighten.