background image

 15 

HUSKYTOOLS.COM 

 

 

Contact 1-888-43-HUSKY for further assistance. 

Maintenance 

 

 

 

 

GENERAL MAINTENANCE 

Humidity in the air causes condensation to form in the air tank. 
This condensation should be drained daily and/or every hour, 
using the instructions found in Draining the tank (on page 14). 

The safety valve automatically releases air if the air receiver 
pressure exceeds the preset maximum. Check the safety valve 
before each use following the instructions found in Checking the 
safety valve (on page 14). 

Inspect the tank yearly for rust, pin holes, or other imperfections 
that could cause it to become unsafe. 

 

AIR COMPRESSOR LUBRICATION 

All the bearings in this tool are lubricated with a sufficient 
amount of high grade lubricant for the life of the unit under 
normal operating conditions. Therefore, no further lubrication of 
the bearings is required. 

 

 

WARNING:

 When servicing, use only identical Husky 

replacement parts. Use of any other parts may create a 
hazard or cause product damage. 

 

WARNING:

 Always wear safety goggles or safety 

glasses with side shields during power tool operation or 
when blowing dust. If operation is dusty, also wear a 
dust mask. 

 

WARNING:

 Always release all pressure, disconnect from 

power supply, and allow unit to cool to the touch before 
cleaning or making repairs on the air compressor. 

 

 

 

 

 

 

Care and Cleaning 

 

 

 

 

Avoid using solvents when cleaning plastic parts. Most plastics 
are susceptible to damage from various types of commercial 
solvents and may be damaged by their use.  

Use clean cloths to remove dirt, dust, oil, grease, etc. 

 

WARNING:

 Do not at any time let brake fluids, gasoline, 

petroleum-based products, penetrating oils, etc., come 
in contact with plastic parts. Chemical can damage, 
weaken or destroy plastic which may result in serious 
personal injury. Electric tools used on fiberglass 
material, wall-board, spackling compounds, or plaster 
are subject to accelerated wear and possible premature 
failure because the fiberglass chips and grindings are 
highly abrasive to bearings, brushes, commutators, etc. 
Consequently, we do not recommend using this tool for 
extended work on these type of materials. However, if 
you do work with any of these materials, it is extremely 
important to clean the tool using compressed air. 

 

 

Содержание H1504ST2

Страница 1: ...ually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Husky USE AND CARE GUIDE 4...

Страница 2: ...are and Cleaning 15 Troubleshooting 16 Service Parts 18 Parts diagram 18 Parts list 19 Symbols 20 Glossary 21 Safety Information PRODUCT FOR CONSUMER USE ONLY Not intended for commercial use DANGER Th...

Страница 3: ...product until you read thoroughly and understand completely the operator s manual Save this operator s manual and review frequently for continuing safe operation and instructing others who may use th...

Страница 4: ...this rule will reduce the risk of deterioration of the enclosure plastic SERVICE 1 Tool service must be performed only by qualified repair personnel Service or maintenance performed by unqualified pe...

Страница 5: ...periodically and if damaged have repaired at your nearest Authorized Service Center Constantly stay aware of cord location Following this rule will reduce the risk of electric shock or fire 22 Never...

Страница 6: ...pressor with a damaged cord since touching the damaged area could cause electrical shock resulting in serious personal injury 4 When working with the air compressor outdoors use an extension cord that...

Страница 7: ...nductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do...

Страница 8: ...er normal wear and tear or any malfunction failure or defect resulting from misuse abuse neglect alteration modification or repair by other than a service center authorized to repair HUSKY branded air...

Страница 9: ...4 2 SCFM 40 PSI Lubrication Oil free Gauges 1 gauge 1 414 in diameter 1 gauge 1 8 in diameter Input 120 V 60 Hz AC only 12 Amps Net weight 44 lbs PACKAGE CONTENTS Part Description A Carry handle B Ma...

Страница 10: ...parts are missing do not operate the compressor until the missing parts are replaced Failure to do so could result in possible serious personal injury WARNING Do not attempt to modify this tool or cr...

Страница 11: ...essure regulator knob G fully clockwise to open the air flow Place the ON OFF switch B in the OFF position and plug in the power cord Open the drain valves K completely Place the ON OFF switch B in th...

Страница 12: ...Lifting Pull the telescopic handle D out until it locks into place NOTE This handle is only for pulling the unit DO NOT lift the unit by this handle To lower handle push it down For lifting the unit...

Страница 13: ...with the pressure regulator knob G Turning the knob fully counterclockwise will completely stop the flow of air NOTE Always use the minimum amount of pressure necessary for your application Using a h...

Страница 14: ...Do not attempt to tamper with safety valve Anything loosened from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve w...

Страница 15: ...es or safety glasses with side shields during power tool operation or when blowing dust If operation is dusty also wear a dust mask WARNING Always release all pressure disconnect from power supply and...

Страница 16: ...the power supply is low Check the voltage from the power supply with a voltmeter The gauge wire or the length of extension cord is wrong Use the correct wire gauge and length extension cord The motor...

Страница 17: ...The humidity is high Move the compressor to an area of less humidity or use an air line filter to reduce moisture discharge in the tank Air is leaking from the compressor The hose connection is loose...

Страница 18: ...18 Service Parts PARTS DIAGRAM...

Страница 19: ...eceiver 1 C1 9048101 Check valve 1 C2 9047086 Quick coupling 2 C3 9047062 Drain valve 2 C4 9051185 Air regulator 1 C5 9049115 Safety valve 1 C6 9063217 Pressure switch 1 C7 9414765 Power switch 1 C8 9...

Страница 20: ...to result in output pressure greater than the marked maximum pressure of the attachment Do not use at a pressure greater than 155 PSI Risk of Fire or Explosion Do not spray flammable liquid in a conf...

Страница 21: ...gs A thread sealing tape must be used to provide a leak free seal on pipe threaded connections Pressure Regulator Knob Regulates the outgoing pressure from the air outlet to the tool It is possible to...

Страница 22: ...Questions problems missing parts Before returning to the store call Husky Customer Service 8 a m 6 p m EST Monday Friday 1 888 43 HUSKY HUSKYTOOLS COM Retain this manual for future use 9039869 A...

Страница 23: ...casa Visite nuestro cibersitio para ver la l nea completa de nuestros productos para satisfacer sus necesidades dom sticas Muchas gracias por haber elegido Husky INSTRUCCIONES DE USO Y MANTENIMIENTO C...

Страница 24: ...sto 19 Gr fico de piezas 19 Lista de piezas 20 S mbolos 21 Glosario 22 Reglas de Seguridad PRODUCTO PARA EL USO DEL CONSUMIDOR SOLAMENTE No destinado al uso comercial PELIGRO Este compresor o bomba no...

Страница 25: ...as instrucciones El incumplimiento de las instrucciones se aladas abajo puede causar descargas el ctricas incendios y lesiones serias ADVERTENCIA Para evitar lesiones corporales serias no intente util...

Страница 26: ...a las herramientas Siga todas las instrucciones de mantenimiento Las herramientas que han recibido el debido mantenimiento se controlan con mayor facilidad 7 Revise para ver si hay desalineaci n o at...

Страница 27: ...la manguera de aire conectada 12 So utilice esta herramienta si no tiene una etiqueta de advertencia 13 So contin e usando ninguna herramienta o manguera que tenga fugas de aire o que no funcione corr...

Страница 28: ...siguiente Cuanto menor es el n mero de calibre mayor es el grueso del cord n Un cord n de un calibre insuficiente causa una ca da en el voltaje de l nea y produce recalentamiento y p rdida de potenci...

Страница 29: ...s reempl celos de inmediato Nunca utilice el compresor con un cord n da ado ya que si toca la parte da ada puede producirse una descarga el ctrica y las consecuentes lesiones serias 4 Al trabajar a la...

Страница 30: ...ras amarillas es el conductor de conexi n a tierra del equipo Si es necesaria la reparaci n o reemplazo del cord n el ctrico o de la clavija no conecte el conductor de conexi n a tierra a una terminal...

Страница 31: ...te para el cliente L MITES DE LA GARANT A Esta garant a no cubre el desgaste debido al uso normal ni ninguna anomal a fallo o defecto producido por el uso incorrecto el abuso la negligencia la alterac...

Страница 32: ...permanente Man metros 1 3 6 cm 1 414 pulg de di metro 1 4 6 cm 1 8 pulg de di metro Corriente de entrada 120 V 60 Hz s lo corr alt 12 A Peso neto 20 Kg 44 lbs CONTENIDO DEL PAQUETE N m ref Descripci...

Страница 33: ...s no utilice el compresor o las herramientas sin haber reemplazado todas las piezas faltantes La inobservancia de esta advertencia puede causar lesiones serias ADVERTENCIA No intente modificar esta he...

Страница 34: ...el flujo de aire Coloque el interruptor B en la posici n de apagado OFF y conecte el cord n de corriente Abra completamente las v lvulas de drenaje K Coloque el interruptor B en la posici n ON y d jel...

Страница 35: ...aci n 1 Transporte 2 Elevaci n Tire telesc pica manillar D hacia fuera hasta que enganche en posici n NOTE Este manillar es s lo para halar la unidad NO ES para usar como asa para levantarla Apretar e...

Страница 36: ...trole la cantidad de caudal de aire con la perilla de regulaci n de la presi n G Si gira el bot n por completo en sentido contrario a las agujas del reloj el caudal de aire se detendr totalmente NOTE...

Страница 37: ...o a la v lvula de drenaje K hasta totalmente cerrada PELIGRO No intente forzar o alterar la v lvula de seguridad Cualquier pieza floja de este dispositivo puede volar y golpearlo La inobservancia de e...

Страница 38: ...el ctricas o al soplar el polvo con aire comprimido Si la operaci n genera mucho polvo tambi n p ngase una mascarilla contra el polvo ADVERTENCIA Siempre purgue toda la presi n desconecte la unidad d...

Страница 39: ...ngitud equivocados Verifique que el calibre y la longitud del cable sean los correctos El devanado del motor tiene corto o est abierto Lleve el compresor a un centro de servicio V lvula de retenci n o...

Страница 40: ...iltro de aire en l nea Fugas de aire Conexi n de la manguera suelta o mal sellada Aseg rese de que las conexiones est n bien ajustadas y selladas con cinta de sellado de hilos Manguera de aire rota o...

Страница 41: ...19 HUSKYTOOLS COM Para ulterior asistencia s rvase contactar con 1 888 43 HUSKY Piezas de Repuesto GR FICO DE PIEZAS...

Страница 42: ...a de regulaci n 1 C2 9047086 Acoplador r pido 2 C3 9047062 V lvula de drenaje 2 C4 9051185 Regulador de aire 1 C5 9049115 V lvula de seguridad 1 C6 9063217 Pres stato 1 C7 9414765 Interruptor de alime...

Страница 43: ...eguridad Riesgo de estallido No ajuste el regulador para producir una presi n de salida superior a la presi n m xima marcada en el aditamento No use una presi n superior a 1069 kPa 155 PSI Riesgo de e...

Страница 44: ...dora de roscas para tener un sello a prueba de fugas en las conexiones roscadas de tubos Perilla de regulaci n de presi n Sirve para regular la presi n de la salida de aire dirigida a la herramienta E...

Страница 45: ...faltantes Antes de devolver el aparato a la tienda contacte con el Servicio de Atenci n al Cliente de Husky de 8 a 16 hora del Este de Lunes a Viernes 1 888 43 HUSKY HUSKYTOOLS COM Guarde este manual...