Husky H1301F Скачать руководство пользователя страница 6

6

7

SYMBOLS

Some of the following symbols may be used on this tool. Please study them and learn their meaning. Proper interpre-
tation of these symbols will allow you to operate the tool better and safer.

Read The Operator’s Manual

Risk of Bursting

Risk of Fire or Explosion

SYMBOL 

NAME 

DESIGNATION/EXPLANATION

Voltage

Current

Frequency (cycles per second)

Type of current

Double-insulated construction

Do not expose to rain or use in damp locations.

To  reduce  the  risk  of  injury,  user  must  read  and  understand 
operator’s manual before using this product.

Eye Protection

Always wear safety goggles, safety glasses with side shields, or 
a full face shield when operating this product.

Precautions that involve your safety.

Do not spray flammable liquid in a confined area. Spray area 
must be well ventilated. Do not smoke while spraying or spray 
where spark or flame is present. Keep compressors as far from 
the spraying area as possible, at least 15 feet from the spraying 
area and all explosive vapors.

Wet Conditions Alert

Class II Construction

Hz

Hertz

A

Amperes

V

Volts

Hot Surface

To reduce the risk of injury or damage, avoid contact with any 
hot surface.

Risk to Breathing

Air obtained directly from the air compressor should never be 
used to supply air for human consumption.

Alternating Current

Safety Alert 

Do not adjust regulator to result in output pressure greater than 
marked maximum pressure of attachment. Do not use at pres-
sure greater than 135 PSI.

Risk of Electrical Shock

Hazardous Voltage: Disconnect from power source before ser-
vicing. Compressor must be grounded.

Содержание H1301F

Страница 1: ...ty ease of opera tion and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for buying a Husky product OPERATOR S MANUAL 1 GALLON PORTABLE AIR COMPRESSOR H1301F ...

Страница 2: ...sor pump is not equipped and should not be used to supply breathing quality air Additional equip ment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 Compressed Gas Association 4221 Walney Road Fifth Floor Chantilly VA 20151 2923 703 788 2...

Страница 3: ...al safety protection will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protec tion equipment When required the employer and user...

Страница 4: ...must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury n Disconnect power supply open drain valve to de compress tank and allow water to drain and allow air compressor to become cool to the touch before servicing Turn pressure regulator knob fully clockwise after shutting off compressor n When servicing a tool u...

Страница 5: ...n this air compressor is capable of providing n Always follow all safety rules recommended by the manufacturer of your air tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal injury n Never direct a jet of compressed air toward people or animals Take care not to blow dust and dirt towards yourself or others Following this rule wi...

Страница 6: ...ns that involve your safety Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spraying area as possible at least 15 feet from the spraying area and all explosive vapors Wet Conditions Alert Class II Construction Hz Hertz A Amperes V Volts Hot Surface To reduce the...

Страница 7: ...ANGER WARNING CAUTION CAUTION Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Without Safety Alert Symbol Indicates a situation that ma...

Страница 8: ... cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension cord heavy enough to carry the current that the compressor will draw An undersized extension cord will cause a drop in line voltage resulting in a loss of power and causing the motor to overheat Use the...

Страница 9: ...d within a metal or plastic hous ing attached to the compressor cylinder head which removes impurity from the intake air of the compressor Air Tank Cylindrical component which contains the compressed air Check Valve Device that prevents compressed air from flowing back from the air tank to the compressor pump Cut In Pressure The low pressure at which the motor will automatically restart Cut Off Pr...

Страница 10: ... 1 5 in diameter Input 120 V 60 Hz AC only 11 5 Amps Net Weight 23 lbs Fig 2 COIL HOSE ON OFF SWITCH SAFETY VALVE TANK PRESSURE GAUGE 90 PSI AIR OUTLET 40 PSI AIR OUTLET POWER CORD DRAIN VALVE BUILT IN CORD WRAP AIR CHUCK 1 4 in NPT MALE CONNECTOR FITTING QUICK COUPLER SEAL THREAD TAPE INFLATION ADAPTER INFLATION NEEDLE INFLATION NOZZLES BLOWER ATTACHMENT 1 4 in NPT FEMALE CONNECTOR FITTING SAFETY...

Страница 11: ...ation and removal of the air hose BUILT IN CORD WRAP A built in cord wrap is provided for convenience in moving and storing the unit OIL FREE UNIVERSAL MOTOR Your air compressor features permanently lubricated bear ings SAFETY VALVE The safety valve is designed to automatically release air if the air receiver pressure exceeds the preset maximum TANK PRESSURE GAUGE The tank pressure gauge indicates...

Страница 12: ...thers n Insert the female connector end of the coil hose into the desired air outlet on the air compressor Push the connector firmly until you hear it click into place n To disconnect the hose push the external ring nut of the quick coupler backward BREAKING IN THE PUMP See Figures 5 6 n Check and tighten all bolts fittings etc n Place the switch in the OFF position and plug in the power cord n Op...

Страница 13: ...o use into the female connector on the other end of the spiral hose WARNING Always ensure the switch is in the OFF O position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible seri ous personal injury n Connect the power cord to the power supply n Turn the switch ON l n Following all safety ...

Страница 14: ...from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand n Turn the air compressor on and allow the tank to fill The compressor will shut off when the pre...

Страница 15: ...using compressed air LUBRICATION All of the bearings in this tool are lubricated with a suffi cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WARNING When servicing use only identical Husky replacement parts Use of any other parts may create a hazard or cause product damage WARNING Always w...

Страница 16: ...electrical appli ances from circuit or operate com pressor on its own branch circuit Check for proper gauge wire and cord length Take compressor to service center Thermal overload protector cuts out repeatedly Low voltage Lack of proper ventilation room temperature too high Wrong gauge wire or length of extension cord Check with voltmeter Move compressor to well ventilated area Check for proper ga...

Страница 17: ...ecified in this operator s manual This warranty does not apply to any damage to the One World Technologies Inc product that is the result of improper maintenance or to any One World Technologies Inc product that has been altered or modified The warranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either INCOMPATIBLE WITH THE ONE WORLD TE...

Страница 18: ...tinent facts when you call or visit Please call 1 866 340 3912 for your nearest Authorized Service Center MODEL NO AND SERIAL NO The model number of this tool will be found on a plate attached to the air tank Please record the model number and serial number in the space provided below HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following information MODEL NUMBER SERIAL NUM...

Отзывы: