19- ENG
D28752
PROBLEM
CAUSE
CORRECTION
Motor will not
run.
Check fuse box for blown
fuse and replace as
necessary. Reset
circuit
breaker. Do not use a fuse or
circuit breaker with higher
rating than that specified for
your particular branch circuit.
Check for proper fuse. You
should use a time delay fuse.
Check for low voltage
problem.
Check the extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Have checked by a Trained
Service Technician.
Fuse blown, circuit breaker
tripped.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
Check the extension cord.
Check wiring connection
inside terminal box.
Содержание D28752
Страница 58: ...58 FR D28752 NOTES...
Страница 59: ...59 FR D28752 NOTES...