The manufacturer does not accept responsibility for any damages that may arise due to non-
observation of these instructions.
 

•   Do not use the unit if it is damaged. If you are in any doubt, consult an engineer.

 

•   Connection and installation of your Husky unit are to be carried out in strict compliance 

with the relevant instructions in this user manual.

 

•   Make sure there is a suitable power outlet (230 volts, 13 amps outlet) with proper 

grounding to power the chiller.

 

•   For safety, the unit must be properly earthed in accordance with specifications.

 

•   Always remember to unplug the unit before cleaning. Never unplug this unit by pulling 

on the power cable. Always grip plug firmly and pull straight out from the socket.

 

•   All electrical repairs must be carried out by a qualified engineer. Inadequate repairs may 

be dangerous.

 

•   Do not damage any parts of the chiller which carry refrigerant by piercing, perforating, 

crushing, twisting or scraping. If refrigerant comes into contact with the eyes it may 
cause serious eye injury.

 

•   Do not obstruct or cover the ventilation aperture.

 

•   Do not allow children to play with the unit, or to sit on it or hang onto the door.

 

 •   This unit is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabil ities, or lack of experience and knowledge, unless they have 
been given supervision or instruction concerning use of the unit by a person responsible 
for their safety.

BEFORE USING FOR THE FIRST TIME

IMPORTANT: Before switching the unit on, we recommend you allow it to stand 
upright for 8 hours. Failure to do this may result in damage to the unit.

 

•   Remove the wooden pallet and the packing.

 

•   To ensure correct operation, it is important that the unit is level.  The cabinet may be 

levelled by turning either or both of the adjustable feet in the front corners.  Use a spirit 
level to check.

 

•   Before operation, we recommend that the cabinet is cleaned for reasons of hygiene and 

to remove any residue left from manufacture.

 

•   For good circulation, vents must not be blocked. Keep a minimum of 100mm of clear 

space around the chiller. Your Husky unit should be placed on flat and firm surface for 
quieter operation.

 

•   Do not expose the unit to direct sunlight or a heat source such as ovens, radiators, 

heaters, etc.

 

•  Do not under any circumstances place heated food or beverages in your Husky 

commercial chiller.

 

•   Do not open the door more often than necessary to lessen the escape of cold air.

 

•   For better air circulation, do not overfill the unit.

 

•  

Adjust the thermostat according to the amount of product and the ambient 
temperature.

Technical Support: 01455 555340 (UK)

UK PRO upright manual 2016 EDITION 2.indd   4

22/12/2015   08:57

Содержание C10PRO-H-C-HU

Страница 1: ... please read this user manual thoroughly before use 2016 Husky Husky reserve the right to change specifications at any time without notice Images used are for illustration only UK PRO upright manual 2016 EDITION 2 indd 1 22 12 2015 08 57 ...

Страница 2: ...C HU with canopy 230v R290 485 2227x650x719 138 C5PRO H HU without canopy 230v R290 485 1985x650x719 133 C8PRO H C HU with canopy 230v R290 795 2227x1000x719 150 C8PRO H HU without canopy 230v R290 795 1985x1000x719 143 C10PRO H C HU with canopy 230v R290 975 2227x1200x719 165 C10PRO H HU without canopy 230v R290 975 1985x1200x719 158 CONTENTS Important Notes 3 Warning Risk of electrical shock haz...

Страница 3: ...pework of your refrigerator is not damaged prior to disposal You can contribute to the environmental awareness by insisting on an appropriate non polluting method of disposal WEEE COMPLIANCE Husky chillers are authorised to carry the CE Conformité Européene and WEEE Waste Electrical and Electronic Equipment Directive symbols The WEEE symbol on this chiller indicates that the product must not be di...

Страница 4: ...al sensory or mental capabil ities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety BEFORE USING FOR THE FIRST TIME IMPORTANT Before switching the unit on we recommend you allow it to stand upright for 8 hours Failure to do this may result in damage to the unit Remove the wooden pallet and...

Страница 5: ...on grille is blocked The chiller is not on a level firm surface or the unit may be touching other items The chiller is vibrating against a neighbouring object Chiller may be close to a water source or leak The door may be opened too often or kept open too long Action Connect the plug to the power supply Call Husky see back page or a qualified engineer Replace the fuse with one of the same rating C...

Страница 6: ...inated When the chiller reaches the set temperature the Refrigeration Light will be off 2 If you do not press any button after six seconds the controller will return to its normal display To switch the chiller off press for six seconds The display will show To switch the chiller back on press for one second The display will show the cabinet temperature and the unit will enter normal working mode D...

Страница 7: ...7 Exploded Diagram Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 7 22 12 2015 08 57 ...

Страница 8: ...ick plate see Fig 5 on page 7 Remove the kick plate by lifting it up and pulling it forward Loosen the thumb screws on either side of the sliding tray see Fig 4 on page 7 With caution slide out the sliding tray no more than 300mm COMPRESSOR QUALIFIED ENGINEERS ONLY To access the compressor slide out the sliding tray see Easy Maintenance Access CLEANING The condenser MUST be cleaned quarterly Caref...

Страница 9: ...ms C4PRO C5PRO Standard models no canopy C4PRO C5PRO Standard models with canopy C8PRO C10PRO Standard models no canopy 9 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 9 22 12 2015 08 57 ...

Страница 10: ...ms C8PRO C10PRO Standard models with canopy C8PRO C10PRO Standard models with door heater no canopy C8PRO C10PRO Standard models with door heater and canopy 10 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 10 22 12 2015 08 57 ...

Страница 11: ...ELECTRONIC THERMOSTAT SF 102SBQ 4 Wiring Diagram 11 Technical Support 01455 555340 UK UK PRO upright manual 2016 EDITION 2 indd 11 22 12 2015 08 57 ...

Страница 12: ...mail service husky co uk Welcome to Husky the home of smart refrigeration We are a leading global refrigeration specialist with over 50 years experience in commercial refrigeration for convenience and hospitality professionals Whatever your requirements we re sure to have a good looking energy efficient model that s perfect for you 221215 Edition 2 UK PRO upright manual 2016 EDITION 2 indd 12 23 1...

Отзывы: