background image

www.spartacogroup.com 

 800-860-6170

9

OPERATING PRECAUTIONS

 PRECAUTION FOR THE TOOL

  PRECAUTION FOR THE CHARGER

1. Select appropriate dies for the connector to be compressed. Incorrect combinations result in 

inferior connections of the conductors. Consult your connector manufacturer for the 

recommended die/connector combinations. 

2. Always point the tool AWAY from other people.

3. If the tool is stored for an extended period at a temperature of less than 25º F (-5ºC), the tool 

should be allowed to return to room temperature to ensure smooth operation Use the tool only 

after it has been at room temperature for 1 hour.

4. Do not drop the tool. Dropping the tool may damage the hydraulic circuit and result in the tool 

not functioning correctly.

5. Keep the head and ram clean and free of debris. Solvents can be used to clean the head, but  

should not be used on the plastic body. Use soap and water to clean the body.

6. Do not use tool for continous use. If any sign of over heating, allow the tool to cool for 15 mins.

7. Do not allow tool to be submerged in water. The tool may be used in damp or wet

 environments. However it is recommended for tool to be air-dried before use.

 PRECAUTION FOR THE BATTERY CARTRIDGE

1. Do not short circuit the contacts or expose the cartridge to water, oil or solvents.

2. Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire.

3. Do not drop or otherwise abuse the battery cartridge.

4. Do not leave the cartridge in locations where it will be exposed to a temperature greater than 

140ºF  (60ºC) for an extended period.

5. The battery has a limited life. When the crimping capacity becomes about 1/2 that of the 

original capacity, the battery should be replaced.

6. If the battery cartridge is stored without being charged, natural drainage will cause the power 

to be  reduced. The battery should be charged every 3 months if not in use.

1.  The LED indicator lights up amber and remains lit when the unit starts charging a battery 

cartridge. The indicator turns green when charging is completed.

2.  The BP-84 can be charged with any of the Huskie Lithium-Ion chargers including the CH-80, 

CH-90 & CH-94. 

3.  Allow battery cartridges to cool before charging. Allow at least 15 minutes between charges 

when charging several cartridges in succession.

4.  Charge batteries at an ambient temperature of 50º-95ºF (10º-35º C). Charging time is 

approximately 50-70 minutes for the BP-84. 

5.  Never short circuit the output terminals.

6.  Do not expose the charger to water, oil or solvents.

7.  Do not disassemble, attempt to modify, drop or otherwise abuse charger.

Содержание SL- BC610

Страница 1: ...10 SL BC610 15 Ton Streamline Compression Tool Read and understand all of the instructions and safety information in this manual before operating or servicing this tool 195 Internationale Blvd Glendal...

Страница 2: ...HANK YOU for purchasing a Huskie Tools product Our mission is to supply the finest steel cable connecting and cutting tools and cable related products to the transmission and distribution markets Husk...

Страница 3: ...containing parts or batteries not originally supplied by Huskie Failure due to misuse improper maintenance misapplication not following instructions or warnings abuse or repairs attempted by anyone o...

Страница 4: ...ye protection when operating this tool Failure to wear eye protec tion could result in serious eye injury from flying debris Electric Shock hazard Use proper personal protective equipment when using t...

Страница 5: ...the streamline design and the traditional C head the new SL BC610 is one of the most versatile 15 ton tools in the market today The new housing design incorporates a rubber over mold handle grip as w...

Страница 6: ...designation are Bluetooth enabled products These tools are able to communicate data to your Bluetooth enabled PC via the downloadable software available on Spartaco website In addition to the audible...

Страница 7: ...lashing quick amber this could be a possible short in the battery circuit or a problem with the charger itself It is best to consult the factory at 1 800 860 6170 for service if such a condition occur...

Страница 8: ...priate size dies for the connector being used 2 Insert half of the die into the C head until the die release push pin is securely locked into the die pin slots Then insert the other half of the die in...

Страница 9: ...BATTERY CARTRIDGE 1 Do not short circuit the contacts or expose the cartridge to water oil or solvents 2 Do not disassemble or attempt to repair the battery cartridge or dispose of in a fire 3 Do not...

Страница 10: ...www spartacogroup com 800 860 6170 10 BREAKDOWN...

Страница 11: ...552 EZ 16 2 66 Plug SL6 03 1 20 PS 6 Pent Seal EZ 14 2 67 Grip R85 05 1 21 P 6 Back Up Ring B C UC 28 2 68 Cylinder BC610 03 1 22 Cylinder Insert EZ 13 2 69 LPH 30 Dust Seal 451 05 1 23 Pump Piston E...

Страница 12: ...Repair Service Defective Suction Valve or Bypass Cartridge Consult Factory for Repair Service MOTOR WILL NOT RUN AT ALL Defective Battery Charge or Replace Battery Bad Contact or Loose Battery Connect...

Страница 13: ...www spartacogroup com 800 860 6170 13 NOTES...

Страница 14: ...www spartacogroup com 800 860 6170 14 NOTES...

Страница 15: ...www spartacogroup com 800 860 6170 15 NOTES...

Страница 16: ...195 Internationale Blvd Glendale Heights IL 60139 Phone 800 860 6170 Fax 800 345 3767 www spartacogroup com...

Отзывы: