24
10.3.3 Replacing the handle
1. Close the rescue unit until a gap of only a few mm remains between the tips. Disconnect
it from the hydraulic power supply unit and clean thoroughly.
2. Remove the fixing screws “A” and remove the handle “B”.
3. Attachment of the handle takes place in the reverse sequence.
NOTE:
The torque required can be taken from the spare parts list of your particular unit.
A