on the load value and is calculated as the current at start
plus 15%.
11.2.8 Emergency Off
The welding process has been interrupted by pressing the
STOP/RESET key.
11.2.9 Heater Coil Error
The dynamic current value during welding differs by more
than 15% from the required value, indicating a short-circuit
in the heater coil.
11.2.10 Power Supply Failure at Last Welding
The last welding is incomplete. The welding unit was dis-
connected from the power supply voltage while it was
in progress. To go on using the unit, this error has to be
acknowledged by pressing the STOP/RESET key (see also
Sect. 9.4).
12
Technical Specifications
Nominal Voltage
230 V
Frequency
50 Hz / 60 Hz
Output Power
2800 VA
Ingress Protection
IP X4
Primary Current
max. 16 A
Ambient Temperature
– 20°C to + 60 °C (– 4°F to
+ 140°F)
Output Voltage
8 V - 48 V
Max. Output Current
110 A
Memory for Welding Reports 1800 reports
Data Interface Port
USB v 2.0 (480 mbit/s)
(see also the information on the data ports in Sect. 6)
Tolerances:
Temperature
± 5 %
Voltage
± 2 %
Current
± 2 %
Resistance
± 5 %
13
Service and Repair Contact
HÜRNER Schweisstechnik
Nieder-Ohmener Str. 26
Tel.: +49 (0)6401 9127 0
35325 Mücke, Germany
Fax: +49 (0)6401 9127 39
Web: www.huerner.de
E-mail: [email protected]