![Hupfer EBR/V19-26 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/hupfer/ebr-v19-26/ebr-v19-26_operating-instructions-manual_2187134035.webp)
Fault Detection and Troubleshooting
Chapter 6
Safety Measures
Page 35
Plate dispenser
4330000_A6
TE-2/V19-26, 27-33 | TE-2/VK19-26 | TEH-1/V19-26, 27-33 | TEH-2/V19-26, 27-33 | TEUH-1/VS19-26 | TEUH-2/VS19-26, 27-33 | TEUH-2/VC19-26
EBR/V19-26, 27-33 | EBRH/V19-26, 27-33 | EBRH-2/V19-26
6
Fault Detection and Troubleshooting
6.1
Safety Measures
DANGER
Hazardous electrical voltage
The electrical voltage may be considerably dangerous to limb and life of per-
sons and lead to injuries.
Before looking for faults, switch off the appliance at the mains. Pull out the
mains plug and insert it into the plug park provided.
ATTENTION
Exposed springs
When pressing down the stacking platform manually, the springs are ex-
posed. Reaching into the gaps of the exposed springs may cause hand inju-
ries.
Never press the stacking platform down manually.
Be careful when hooking and unhooking the springs. When adjusting springs
on sharp edges, pay particular attention to the ends of the tension springs.
6.2
Notes on Troubleshooting
Please check first whether there is an operating fault. You can eliminate some faults on your own.
Service work should only be carried out by authorised specialists.
Defective components should only be replaced with original parts.
In the event of after-sales service and when ordering spare parts specify the data given in the rating plate.
Inspection and maintenance intervals depend on the use of the appliance. Consult your dealer's after-sales
service department.
Regular inspection and maintenance of the appliance prevent disruptions to operation and ensure safety.
6.3
Fault and Action Table
Fault
Possible cause
Action
Appliance does not become warm;
indicator light does not come on.
Defective building fuses.
Check fuse and repair, if necessary.
Appliance does not become warm;
indicator light does not come on.
Defective On / Off switch.
Switch off the appliance at the mains
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Appliance does not become warm;
indicator light does not come on.
Defective lead or mains plug
Switch off the appliance at the mains
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Appliance does not become warm;
indicator light is on.
Thermostat is defective.
Take the appliance out of operation
and have it checked and repaired by
authorised specialist staff, if neces-
sary.
Appliance becomes warm; indicator
light does not come on.
Defective indicator light.
Take the appliance out of operation
and have it checked and repaired by
authorised specialist staff, if neces-
sary.