4. About input alarm port
4.1 Disable the digital inputs
pwd#DA#
Tips: if you want to use the digital inputs, please enable it firstly.
4.2 Enable the digital inputs
pwd#EA#
Tips: if you enable the digital inputs function, the sensors will enter Armed status after 10minutes of the
latest dial-in. in the first 10minutes, when the sensor triggered, will not alarm, after 10minutes, the unit in
armed mode, when any sensor triggered, will start the siren (if you connected) or switch on the light(if
you connect it) around 5 seconds and send SMS to the Position 01 and 02 authorized numbers
immediately.
Siren+ output is DC12V output, it cann’t be controlled by SMS command.it only will be triggered around
5 seconds when alarm input triggered.
4.3 Inquiry Alarm Setting
pwd#AL?
Reply:
Alarm Inputs Disabled or Alarm Inputs Enabled.
Tips: Alarm Inputs Disabled means disable the digital inputs, Alarm Inputs Enabled means Enable
digital inputs.
4.4 Alarm input working mode selection
pwd#M2#
For M2 working mode,alarm would be triggered according to your KEYNO or KEYNC selection
pwd#M3#
For M3 working mode,Alarm input status is changed,then will trigger the alarm
4.5 Modify the digital input type (Working for M2 mode)
pwd#KEYNC#
Modify the digital input type as NC; if the sensor you used with this unit is NC, then you should set the
unit as NC type.
pwd#KEYNO#
Modify the digital input type as NO; if the sensor you used with this unit is NO, then you should set the
unit as NO type.
4.6 Alarm SMS Text presetting
Predefined your customized SMS Text message for alarm In1 and In2 (if password is 1234)
In1 Open Alarm Content:
1234#TEXT1Owsd1Openalarm#
In1 Close Alarm Content:
1234#TEXT1Cwsd1Closealarm#
In2 Open Alarm Content:
1234#TEXT2Owsd2Openalarm#
In2 Close Alarm Content:
1234#TEXT2Cwsd2Closealarm#
wsd1Openalarm, wsd1Closealarm, wsd2Openalarm, wsd2Closealarm are the Customized Message
text to be sent when alarm happen
4.7 Check the Alarm SMS Text
pwd#ALARMTEXT?#
5. About Customized SMS Command
Tips: Normally you can use the phone calling to control the device,but sometimes maybe you need to
use the SMS to control the output with a temporarily timer control or temporarily ON or OFF ,and you
don’t nee to change the device setting.
Customize Relay Output ON Command:
1234#ON-TEXT=XXXXXX
Customize Relay Output OFF Command:
1234#OFF-TEXT=XXXXX
Customize Relay Ouput Timer Control: 1234#TOG-TEXT=XXXXX
Содержание RTU5015 Plus