HUOBEI electronics RTU5015 Plus Скачать руководство пользователя страница 4

4. About input alarm port 

4.1 Disable the digital inputs   

pwd#DA# 

Tips: if you want to use the digital inputs, please enable it firstly.   

4.2 Enable the digital inputs   

pwd#EA# 

Tips: if you enable the digital inputs function, the sensors will enter Armed status after 10minutes of the 

latest dial-in. in the first 10minutes, when the sensor triggered, will not alarm, after 10minutes, the unit in 

armed mode, when any sensor triggered, will start the siren (if you connected) or switch on the light(if 

you connect it) around 5 seconds and send SMS to the Position 01 and 02 authorized numbers 

immediately.   

Siren+ output is DC12V output, it cann’t be controlled by SMS command.it only will be triggered around 

5 seconds when alarm input triggered. 

4.3 Inquiry Alarm Setting 

pwd#AL? 

Reply:

 

Alarm Inputs Disabled or    Alarm Inputs Enabled.   

Tips:    Alarm Inputs Disabled means disable the digital inputs, Alarm Inputs Enabled means Enable 

digital inputs.   

4.4 Alarm input working mode selection 

pwd#M2# 

For M2 working mode,alarm would be triggered according to your KEYNO or KEYNC selection 

pwd#M3#   

For M3 working mode,Alarm input status is changed,then will trigger the alarm 

4.5 Modify the digital input type (Working for M2 mode) 

pwd#KEYNC# 

Modify the digital input type as NC; if the sensor you used with this unit is NC, then you should set the 

unit as NC type. 

pwd#KEYNO# 

Modify the digital input type as NO; if the sensor you used with this unit is NO, then you should set the 

unit as NO type. 

4.6 Alarm SMS Text presetting 

Predefined your customized SMS Text message for alarm In1 and In2 (if password is 1234)   

In1 Open Alarm Content:   

 

1234#TEXT1Owsd1Openalarm# 

 

In1 Close Alarm Content:   

 1234#TEXT1Cwsd1Closealarm# 

 

In2 Open Alarm Content:   

 

1234#TEXT2Owsd2Openalarm# 

 

In2 Close Alarm Content:   

 1234#TEXT2Cwsd2Closealarm# 

wsd1Openalarm, wsd1Closealarm, wsd2Openalarm, wsd2Closealarm are the Customized Message 

text to be sent when alarm happen 

4.7 Check the Alarm SMS Text 

pwd#ALARMTEXT?# 

5. About Customized SMS Command 

Tips: Normally you can use the phone calling to control the device,but sometimes maybe you need to 

use the SMS to control the output with a temporarily timer control or temporarily ON or OFF ,and you 

don’t nee to change the device setting. 

Customize Relay Output ON Command:   

1234#ON-TEXT=XXXXXX 

 

Customize Relay Output OFF Command:   

1234#OFF-TEXT=XXXXX 

 

Customize Relay Ouput Timer Control:   1234#TOG-TEXT=XXXXX 

Содержание RTU5015 Plus

Страница 1: ... gate or garage door with a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone GSM Gate Opener GSM Remote Switch RTU5015 Plus User Manual Ver 1 6A Date Issued 2016 08 01 All rights reserved by HUOBEI ELECTRONICS ...

Страница 2: ...rized number then carries out the turn ON OFF action Moreover the RTU5015Plus has 2 digital inputs for alarm inputs when any one of the inputs triggered will send SMS Alert the to owners immediately in the meanwhile the RTU5015Plus start the siren DC12V out for 5 seconds This is very useful if you need protect your assets with low cost solution The Device LEDs and terminal descriptions are the fol...

Страница 3: ... in the memory 2 4 Remove the Authorized Number pwd 0000 Serial Number E g if you want to remove the authorized number at position 12 and the password is 1234 then you can send 1234 TEL 0000 012 then will overwrite the posion with number 0000 to remove it 3 About system parameters 3 1 Working mode selection security mode or free control mode pwd AU This command allows only the authorized numbers c...

Страница 4: ...Alarm input status is changed then will trigger the alarm 4 5 Modify the digital input type Working for M2 mode pwd KEYNC Modify the digital input type as NC if the sensor you used with this unit is NC then you should set the unit as NC type pwd KEYNO Modify the digital input type as NO if the sensor you used with this unit is NO then you should set the unit as NO type 4 6 Alarm SMS Text presettin...

Страница 5: ...d it will still send the alarm SMS Important Tips When power off time over five minutes or first time to use Only when normal power supply time is more than 2 minutes then battery start to work 7 About the device status change report For RTU5015 Standard version that Report is limited to the relay status change but for RTU5015Plus any device status change or SMS command will be reported pwd N When...

Страница 6: ......