The SMS commands used in the GSM Gate Opener are the following:   

1. About password 

1.1 Setup New Password   

(Only use four digital number as the password)

 

pwd#PWDnewpassword#PWDnewpassword# 

if successful, the unit will return: PWD SETUP OK.  

For example, the original password is 1234, you want change it to 6666, then you can send the 

command below: 1234#PWD6666#PWD6666# 

1.2 Reset the Password 

If you want to reset to factory default, then please send “RESET ” to it within 2 minutes after switch on 

the RTU5015. ( After 2 minutes working,then the RTU5015 can not respond this command ) 

2. About Authorized numbers 

2.1 Setup Authorized number   

pwd#TELAuthorized Number#Serial Number#   

E.g.: if you want to setup 63648495 as the first user number, and the password is 1234,then you can 

send 1234#TEL63648495#001# to the RTU5015 unit.   

 

 

 

 

 

 

2.2 Inquiry the Serial Number’s Authorized number   

pwd#TELSerial Number?# 

E.g.: If you want to know the authorized number at position 2, and the password is 1234,then you can 

send 1234#TEL002?# to check it.   

2.3 Search a Phone number in the RTU5015 memory 

pwd#FINDphone number# 

E.g.: If you forget which position of the number: 63648495, then you can send 1234#FIND63648495# to 

search it in the memory. 

2.4 Remove the Authorized Number 

pwd#0000#Serial Number#   

E.g.: if you want to remove the authorized number at position 12, and the password is 1234, then you 

can send 1234#TEL#0000#012#, then will 

overwrite the posion with number “0000” to remove it

 

3. About system parameters 

3.1 Working mode selection (security mode or free control mode) 

pwd#AU#   This command allows only the authorized numbers can access 

pwd#AA#   This command allows any numbers to call the SIM number to access 

pwd#AC?#   

Check the setting of working mode 

3.2 Setup the relay close time 

pwd#GOTTime# 

   The GOT parameters should be in 0~60000 ( 0~30000 seconds )   

 

 

 

 

 

Tips:  

1. the authorized number means the one who can dial the RTU5015 unit to open it.   

2.We strongly recommend that the serial number of 01 and 02 are cellphone number, because of 

the alarm message only send to the first and second position numbers;   

3. The Serial Number is the position to store the authorized number, from 001~999.   

This command is used to setup the Relay working time when triggered. The default time is 5.0 

seconds. You can change it with the GOT command. The relay closed time is half as the number 

you set, e.g.: if you set pwd#GOT19#, means the relay closed 19/2=9.5Seconds.     

To check the value, you can use the command pwd#GOT?#

 

, the unit will reply the current value.   

If you want to let the relay works at switch mode, then you can set the time as 00 

Содержание RTU5015 Plus

Страница 1: ... gate or garage door with a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone GSM Gate Opener GSM Remote Switch RTU5015 Plus User Manual Ver 1 6A Date Issued 2016 08 01 All rights reserved by HUOBEI ELECTRONICS ...

Страница 2: ...rized number then carries out the turn ON OFF action Moreover the RTU5015Plus has 2 digital inputs for alarm inputs when any one of the inputs triggered will send SMS Alert the to owners immediately in the meanwhile the RTU5015Plus start the siren DC12V out for 5 seconds This is very useful if you need protect your assets with low cost solution The Device LEDs and terminal descriptions are the fol...

Страница 3: ... in the memory 2 4 Remove the Authorized Number pwd 0000 Serial Number E g if you want to remove the authorized number at position 12 and the password is 1234 then you can send 1234 TEL 0000 012 then will overwrite the posion with number 0000 to remove it 3 About system parameters 3 1 Working mode selection security mode or free control mode pwd AU This command allows only the authorized numbers c...

Страница 4: ...Alarm input status is changed then will trigger the alarm 4 5 Modify the digital input type Working for M2 mode pwd KEYNC Modify the digital input type as NC if the sensor you used with this unit is NC then you should set the unit as NC type pwd KEYNO Modify the digital input type as NO if the sensor you used with this unit is NO then you should set the unit as NO type 4 6 Alarm SMS Text presettin...

Страница 5: ...d it will still send the alarm SMS Important Tips When power off time over five minutes or first time to use Only when normal power supply time is more than 2 minutes then battery start to work 7 About the device status change report For RTU5015 Standard version that Report is limited to the relay status change but for RTU5015Plus any device status change or SMS command will be reported pwd N When...

Страница 6: ......

Отзывы: