The SMS commands used in the GSM Gate Opener are the following:
1. About password
1.1 Setup New Password
(Only use four digital number as the password)
pwd#PWDnewpassword#PWDnewpassword#
if successful, the unit will return: PWD SETUP OK.
For example, the original password is 1234, you want change it to 6666, then you can send the
command below: 1234#PWD6666#PWD6666#
1.2 Reset the Password
If you want to reset to factory default, then please send “RESET ” to it within 2 minutes after switch on
the RTU5015. ( After 2 minutes working,then the RTU5015 can not respond this command )
2. About Authorized numbers
2.1 Setup Authorized number
pwd#TELAuthorized Number#Serial Number#
E.g.: if you want to setup 63648495 as the first user number, and the password is 1234,then you can
send 1234#TEL63648495#001# to the RTU5015 unit.
2.2 Inquiry the Serial Number’s Authorized number
pwd#TELSerial Number?#
E.g.: If you want to know the authorized number at position 2, and the password is 1234,then you can
send 1234#TEL002?# to check it.
2.3 Search a Phone number in the RTU5015 memory
pwd#FINDphone number#
E.g.: If you forget which position of the number: 63648495, then you can send 1234#FIND63648495# to
search it in the memory.
2.4 Remove the Authorized Number
pwd#0000#Serial Number#
E.g.: if you want to remove the authorized number at position 12, and the password is 1234, then you
can send 1234#TEL#0000#012#, then will
overwrite the posion with number “0000” to remove it
3. About system parameters
3.1 Working mode selection (security mode or free control mode)
pwd#AU# This command allows only the authorized numbers can access
pwd#AA# This command allows any numbers to call the SIM number to access
pwd#AC?#
Check the setting of working mode
3.2 Setup the relay close time
pwd#GOTTime#
The GOT parameters should be in 0~60000 ( 0~30000 seconds )
Tips:
1. the authorized number means the one who can dial the RTU5015 unit to open it.
2.We strongly recommend that the serial number of 01 and 02 are cellphone number, because of
the alarm message only send to the first and second position numbers;
3. The Serial Number is the position to store the authorized number, from 001~999.
This command is used to setup the Relay working time when triggered. The default time is 5.0
seconds. You can change it with the GOT command. The relay closed time is half as the number
you set, e.g.: if you set pwd#GOT19#, means the relay closed 19/2=9.5Seconds.
To check the value, you can use the command pwd#GOT?#
, the unit will reply the current value.
If you want to let the relay works at switch mode, then you can set the time as 00