Huntleigh IRT10 Скачать руководство пользователя страница 3

4

Ta

ble of

 Contents

    

Notice

This document contains proprietary information that is protected by copyright. All Rights 
Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, 
except as allowed under the copyright laws.

Warranty

The information contained in this document is subject to change without notice.
Huntleigh Healthcare Ltd makes no warranty of any kind with regard to this material, including, 
but not limited to, the implied warranties or merchantability and 

fi

 tness for a particular purpose.

Huntleigh Healthcare Ltd shall not be liable for errors contained herein or for incidental or 
consequential damages in connection with the furnishing, performance, or use of this material.

Revision History

The documentation part number and revision number indicate its current edition. The revision 
number changes when a new edition is printed in accordance with the revision history of the 
documentation. Minor corrections and updates which are incorporated at reprint do not cause 
the revision number to change. The document part number changes when extensive technical 
changes are incorporated.

© Huntleigh Healthcare Ltd
All rights reserved

The IRT10 is in conformity with the Medical Devices Directive 93/42/EEC as 

amended by 2007/47/EC and has been subject to the conformity assurance 
procedures laid down by the Council Directive.

Manufactured in the UK by Huntleigh Healthcare Ltd. 

As part of the ongoing development programme the company reserves the right 

to modify speci

fi

 cations and materials without notice. 

Smartsigns

®

 and Huntleigh are registered trademarks of Huntleigh Technology 

Ltd. 

     © Huntleigh Healthcare Ltd. 2017

Содержание IRT10

Страница 1: ...Wireless Tympanic Thermometer IRT10...

Страница 2: ...ts 11 4 3 Connecting the Thermometer to the host 11 4 4 Installing the Batteries 12 4 5 Pairing the Thermometer and Main Unit 12 5 Using the Thermometer 13 5 1 Temperature Measurement 13 6 Care Cleani...

Страница 3: ...on History The documentation part number and revision number indicate its current edition The revision number changes when a new edition is printed in accordance with the revision history of the docum...

Страница 4: ...use and ensure its safe and proper use WARNING Before use carefully read directions for use including all warnings cautions and instructions WARNING If the battery shows any signs of damage leakage or...

Страница 5: ...ital Signs Monitor 2 1 Features of the IRT10 Wireless Themometer Physical The IRT10 wireless tympanic thermometer is a clinical grade hand held thermometer indicated for the intermittent measurment of...

Страница 6: ...uld not be used if the following situations are present Do not use the thermometer if there is any blood or drainage in the ear canal Do not use the thermometer if the patient presents with inflamator...

Страница 7: ...trols Indicators Symbols and Displays 3 5 Thermometer Controls and Display 1 2 3 4 5 6 1 Temperature probe status indicator 2 Start measurment 3 Display 4 Infra red sensor 5 Lens ejector 6 Battery com...

Страница 8: ...ption of Symbols Indicators The symbols and Indicators are described as follows Symbols Description Attention consult accompanying documents Battery charging indicator lamp Refer to instructions for u...

Страница 9: ...ormit Europ enne Complies with medical device directive 93 42 EEC Disposal instructions Manufacturer This way Up Fragile Handle with care Limit of stacking layers Keep dry Description of Controls Indi...

Страница 10: ...ing and Inspection The Thermometer is shipped in one carton Examine the carton carefully for evidence of damage Contact Huntleigh Healthcare Ltd Service Department immediately if any damage is discove...

Страница 11: ...y compartment Place new batteries into compartment paying attention to the polarity close the compartment ensuring it snaps into place The system is ready for use 4 5 Pairing the Thermometer and Main...

Страница 12: ...ens cover in accordance with the local regulations During the monitoring process the temperature measuring instrument will automatically check itself once per hour Self checking will last 2 seconds an...

Страница 13: ...hat the measurement is complete 5 Remove the thermometer 6 The measurement will be shown on the thermometer s screen it will be automatically transferred to the monitor Thermometer display Monitor dis...

Страница 14: ...n is not available use a suitable carton with appropriate packing material to protect the device during shipping Return by any shipping method that provides proof of delivery 6 3 Service Apart from a...

Страница 15: ...f range 10 40 C 33 8 39 2 F Move the device to appropriate environment and wait 30 minutes prior to taking a temperature Er2 The environment temperature is not stable Do not take measurement until the...

Страница 16: ...The Smartsigns Compact 300 should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary the Smartsigns Compact 300 should be observed to verify norm...

Страница 17: ...may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a The ISM industrial scientific and medical bands between 150 k...

Страница 18: ...e s 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 6100...

Страница 19: ...power of transmitter W Separation distance according to frequency of transmitter m 150kHz to 80MHz d 1 2 P 80MHz to 800MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1...

Страница 20: ...AMMABLE ANAESTHETIC MIXTURE WITH AIR OXYGEN OR NITROUS OXIDE 9 2 Standards MDD 93 42 EEC EN ISO13485 2012 AC2012 EN ISO14971 2012 EN 60601 1 2006 AC 2013 EN 60601 1 2 2007 AC 2010 EN60601 1 6 2010 EN...

Страница 21: ...700 hPa to 1060 hPa Note The system may not meet its performance specifications if stored or used outside the manufacturer s specified temperature and humidity range 9 5 Measurement Parameters Probe T...

Страница 22: ...aned to the outside of the package Mark the package Service Department For further details refer to NHS document HSG 93 26 UK only Huntleigh Diagnostics reserve the right to return product that does n...

Страница 23: ...rjoHuntleigh House Houghton Hall Business Park Houghton Regis Bedfordshire LU5 5XF Registered No 942245 England Wales Registered Office Huntleigh Healthcare Limited 2017 As our policy is one of contin...