background image

10

The selected days will show with a   to indicate their 

status ON. The last   is the last watering day for 

the program.

 

Selecting Interval Watering

With this option you can select interval watering from 

1 to 31 days.
1.  With the   cursor on day 7, press the   button until 

the 

 interval watering icon and the two calendars 

appear on the display.

2.  Press the   or   button to select the number of 

days between watering days (1 to 31). This is called 

the interval.

The controller will water the next Start Time and will then 

water at the interval programmed.

Programming Stations to Operate Together 

(SVC-200 & SVC-400)

The SVC-200 and SVC-400 allow for automatic watering of 

multiple valves at the same time. Up to four stations can 

operate at the same time. If more than one station has the 

same start time, they will operate together (they must also 

be programmed with the same water day). For example, 

if Station 1 and 2 both have been programmed with start 

times of 8:00 am, they will both turn on and run at the 

same time.
The SVC allows for start time stacking which is helpful 

when system capacity is not adequate to support the opera-

tion of multiple valves at the same time. Let's assume a 

scenario in which Station 1 is programmed to start at 8:00

 

AM

 

and run for 15 minutes, and Station 2 is programmed to 

start at 8:10

 

AM

 

and run for 15 minutes. Station 1 watering 

run time overlaps Station 2 start time. The SVC will wait 

until Station 1 completes watering until it starts Station 2. 

In this scenario, Station 2 will start at 8:15 am.

 

System Off

This function permits the user to shut the system off for an 

indefinite period of time.
1.  Press the mode button   until the 

 Crossed Sprin-

kler icon is displayed.

2.  Wait 4 seconds and “Off” will appear on the display. 

The SVC is now in the System Off mode and will remain 

off until it is turned back on again.

PROGRAMMING (Continued)

Содержание SVC

Страница 1: ...o FR Programmateur Autonome Guide de l utilisateur et Instructions d installation IT Programmatore per Valvole Intelligente Guida per l utente ed istruzioni per l installazione DE Das Intelligente Magnetventil Steuergerät Hinweise zur installation und bedienungsanleitung PRT Programador de Válvulas Inteligente Guia do utilizador e instruções de instalação ...

Страница 2: ......

Страница 3: ...Start Times 8 Eliminating a Start Time 9 Setting the Run Time Length of Watering 9 Setting Days to Water 9 Selecting Specific Days of the Week to Water 9 Selecting Interval Watering 10 Programming Stations to Operate Together SVC 200 SVC 400 10 System Off 10 To Activate the Controller from the System Off Mode 11 Programmable Rain Off 11 Manual Watering 11 To Suspend Manual Watering to All Stations...

Страница 4: ...ow battery status shows status of life of battery Rain sensor or other micro switch sensor compatible Multiple mounting options Non volatile memory retains all program information LCD Display 1 Main Display Indicates all programmed information 2 Station Number Indicates the station number being programmed 3 Current Time Day Icon indicates when current day and clock are being set 4 Run Times Icon i...

Страница 5: ...ng life of the battery in the SVC 13 Manual On Off Icon indicates when manual watering is programmed Allows the user to activate the station manually 14 Sensor Interrupted Icon indicates that the rain sensor has shut down the system 15 Watering Icon indicates that watering is occurring Control Buttons Button Increases the selected flashing display Button Decreases the selected flashing display But...

Страница 6: ...is inside the battery compartment Screw the SVC body halves together to seal the compartment The SVC uses a standard 9 volt alkaline battery not included to operate the valve and program the controller Under normal conditions the battery should provide at least one full year of service Use of a 9 volt lithium battery will extend the service life of the SVC between battery changes approximately 3 y...

Страница 7: ...ads from each solenoid to the single common wire black lead coming from the SVC Secure all wire connections with waterproof connectors 2 Attach one red wire from each solenoid to the cor responding station wire red lead from the SVC The station numbers are identified on the face of the SVC Secure all wire connections with waterproof connectors NOTE The maximum wire distance between the solenoid an...

Страница 8: ...ounting clip to the solenoid Mounting Clip Mounting Clip Mounting Adapter Along with the universal mounting clip a mounting adapter is also provided with the SVC This mounting adapter allows for alternate methods of mounting the controller either to the side of the valve box or stake mounted within the valve box Valve Box Mounting Method Figure 2 1 Position the universal mounting adapter on the si...

Страница 9: ...nsor is to stop watering when weather conditions dictate NOTE When the Rain Sensor is interrupt ing the watering the display will show the System Off icon OFF and on the display 1 Cut the yellow wire loop attached to the SVC at approxi mately the middle of the loop 2 Remove approximately 13mm of insulation from each wire Attach one yellow wire to each of the wires of the weather sensor You can mou...

Страница 10: ...ress the button until the Current Time Day icon is displayed 2 Hours will be flashing Press the or button to change the hour shown on the display Press the to proceed to setting the minutes 3 Minutes will be flashing Use the or button to change the minutes shown on the display Press the to proceed to select AM PM or 24 hour time 4 The time will be displayed and the time of day flashing Press the o...

Страница 11: ...ng 1 Press the button until the Run Time icon is displayed 2 The display will show the last run time entered 3 Use the or button to change the station run time on the display from 1 minute to 4 hours 4 Press the button to navigate to the next station number to be programmed Setting Days to Water 1 Push the button until the Water Days icon is displayed The station number will also be displayed 2 Th...

Страница 12: ...so be programmed with the same water day For example if Station 1 and 2 both have been programmed with start times of 8 00 am they will both turn on and run at the same time The SVC allows for start time stacking which is helpful when system capacity is not adequate to support the opera tion of multiple valves at the same time Let s assume a scenario in which Station 1 is programmed to start at 8 ...

Страница 13: ...ays off desired up to 7 The SVC will wait the number of days selected and then reactivate automatic watering Manual Watering The SVC features a simple one touch manual start One or more stations can be programmed to run manually at the same time To Activate a Manual Watering 1 Press the button once to display the current time of day 2 Press and hold the button for two seconds to display the Manual...

Страница 14: ...f the stations operating manually 2 When the station number appears for the station that you would like to suspend manual watering press the button once The time remaining displayed will change to Off and the station will turn off 3 Repeat steps 1 and 2 to suspend watering for additional stations The battery life status icon is a quick way to determine the remaining life of the installed battery w...

Страница 15: ...ion does not start at start time Controller in System Off mode AM PM of time of day not set correctly AM PM of start time not set correctly Verify that controller is programmed for automatic watering Correct AM PM of time of day Correct AM PM of start time Rain sensor does not suspend watering Rain sensor defective or miswired Verify proper operation of the rain sensor and wire connections see pag...

Отзывы: