background image

www.hunterfan.com

Model 30546 & 30547

(remote included)

41959-01   03/30/2006

© 2006 Hunter Fan Company

Replacement Filter Information

MODEL

PRE-FILTER

30546

30901

30547

30901

41959-01_3.30.06.pmd

3/30/06, 3:15 PM

1

Содержание PermaLife 30546

Страница 1: ...w hunterfan com Model 30546 30547 remote included 41959 01 03 30 2006 2006 Hunter Fan Company Replacement Filter Information MODEL PRE FILTER 30546 30901 30547 30901 41959 01_3 30 06 pmd 3 30 06 3 15 PM 1 ...

Страница 2: ...0 Using the Ionizer 11 Override of Auto Mode 12 Filter Run Time Counters 13 Programming Setting Day and Time 14 Pre set Programming 15 User Programming 16 Reviewing Programs 18 Locking Unlocking the Keypad 18 Resetting the Air Purifier 19 Air Purifier Maintenance Cleaning Your Air Purifier 20 Changing the Pre Filter 20 Cleaning the Filter 21 Obtaining Replacement Filters 22 Troubleshooting Problem...

Страница 3: ... INSTRUCTIONS Introduction Thank you for purchasing the PermaLife Air Purifier from Hunter Fan Company You have pur chased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe The following innovative features are included in your Hunter Air Purifier High Particulate Efficiency The cleanable filter will remove 99 5 of 0 5 mi...

Страница 4: ...air is pulled into the purifier the activated carbon pre filter absorbs odors and catches large particles Then the air travels through the PermaLife Cleanable Filtration System where the smaller particles are collected Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Finally the clean purified air is released back into the room Fi...

Страница 5: ...mming modes FILTER RESET Resets the pre filter and filter counters FIlter run time counters on page 13 DISPLAY Selects the clock pre filter or fil ter display Display modes on page 9 DAY TIME Used to set the day and time Setting day and time on page 14 PROGRAM Allows you to enter program mode and define user programs User pro gramming on page 16 RESET Returns unit to factory settings Re setting th...

Страница 6: ... by placing your fingers under the handle and pulling the front grill towards you and then up Refer to Fig 5 Fig 5 PULL FORWARD THEN UP HANDLE 3 Next check the cleanable filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 The carbon pre filter is mounted inside the front grill with hook tape Confirm that it properly covers the g...

Страница 7: ...All dis play features except the day and time will go blank and the hour will flash 2 Use the UP DOWN keys to adjust the hour Tapping the key will advance the hour by increments of one Holding down the key will change the hour rapidly Note the AM PM indicator as you cycle through a 24 hour period 3 Press the DAY TIME key again Now the minutes will be flashing Use the UP DOWN keys to adjust the min...

Страница 8: ...not mix alkaline stan dard carbon zinc or rechargeable nickel cadmium batteries 2 To use the remote point it at the air purifier then press and release the appropriate key The key functions are as follows 0 OFF 1 LOW 2 MEDIUM and 3 HIGH When using the remote the air purifier remains in the mode that it is currently set for When the keypad is locked the remote may still be used to adjust the speed ...

Страница 9: ...fer to Filter Run Time Counters for additional information pg 13 Filter Display The Filter Display mode tells you how many hours the filter has been in use In addition to the run hours you will see the Filter indicator If the run hours have reached 2800 hours ap proximately 1 year of use the Filter indicator will flash to remind you to check the filter Refer to Filter Run Time Counters for more de...

Страница 10: ...ier is pre programmed for all 7 days of the week as shown below Refer to User Programming on pg 16 for instruc tions on changing the programs When using the remote the air purifier remains in the mode that it is currently set for Table 1 Pre set Programming Provided for Each Air Purifier To switch between Manual and Auto Modes 1 To change operating modes press the AUTO key The current operating mo...

Страница 11: ...s are also more easily captured by the cleanable filter as they pass through the PermaLife Cleanable Filtration System To ensure the best air circulation in the room we recommend that you place your air purifier six 6 inches away from any walls To turn the ionizer on or off 1 To turn the ionizer on press the IONIZER key The word IONIZER will appear in the lower left corner of the display 2 To turn...

Страница 12: ...just to the new setting The current program number will flash to signify the temporary override To end the temporary override 1 The temporary override will autmatically end at the next scheduled program change 2 To immediately end the temporary override and re turn to the program press theAUTO key twice The air purifier will return to Auto Mode and the sched uled program Permanent Override To begi...

Страница 13: ...ilter are displayed 2 The display shows the number of run hours since the counter was reset Although the maximum display value is 9 999 hours the counters can go indefinitely To indicate that the counter is over 9 999 hours the display will flash For example a run time of 12 000 hours is represented by a flashing 2 000 hours The values of the Pre Filter and Filter Counters are stored in the air pu...

Страница 14: ...ill flash 2 Use the UP DOWN keys to adjust the hour Tapping the key will advance the hour by increments of one Holding down the key will change the hour rapidly Note the AM PM indicator as you cycle through a 24 hour period 3 Press the DAY TIME key again Now the minutes will be flashing Use the UP DOWN keys to adjust the minute Tapping the key will change the minute by in crements of one and holdi...

Страница 15: ...unning If no value is changed then the frozen time will be replaced by the internal clock when you exit the Day Time setting mode If the power is lost to the unit the memory will maintain the clock for at least 12 hours Pre set Programming As discussed in the Manual and Auto Operating Modes section of the manual pg 10 your air purifier comes with pre set programs For your reference these programs ...

Страница 16: ... next setpoint time is reached The setpoint time can only be set in 10 minute increments Blower speed ranges from 0 to 3 Zero indicates that the blower is turned off a setting of 1 is low 2 is medium and 3 represents a blower speed of high If you want the weekdays and the weekends to be identical you should program both the weekday programs and the weekend programs with the same values If you use ...

Страница 17: ...rogram for weekdays 5 The display will advance to the second program for weekdays with the hour position flashing Follow steps 2 to 4 to set the second program After setting each pro gram the display will advance to the next program num ber After going through all four weekday programs the unit will advance through each of the four weekend pro grams The adjustment procedure steps 2 to 4 is the sam...

Страница 18: ... The display will stop on that program and allow you to make changes Refer to User Programming pg 16 for more details on how to change the values Locking Unlocking the Keypad Once you enter the desired programs you may want to lock the keypad to prevent accidental changing of the programs When the keypad is locked all keys will be disabled If you press a key Lock will be displayed on the screen fo...

Страница 19: ...f the week and programs will default to their factory settings and the unit will turn off The only information that will be saved is the pre filter and filter counter values If you still have problems after resetting the air purifier please contact Hunter for additional assistance refer to Technical Assistance pg 23 To Reset the Air Purifier 1 Using a small pin or paperclip hold down the RESET key...

Страница 20: ...r will flash as a reminder that you should replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 1400 hours approximately 3 months of use If neces sary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of the cleanable filter Refer to Obtaining Replacement Fi...

Страница 21: ...ist to help determine if the filter should be cleaned Compare the color of the filter to the color coded chart on the inside of the housing If the filter color matches the darkest color on the chart you should clean the filter If you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Clean the filter to return to normal operation T...

Страница 22: ... DISPLAY key until the filter counter is displayed Then hold the FILTER RESET key for 2 seconds The filter counter will return to zero and resume counting Obtaining Replacement Filters To obtain replacement filters for your air purifier first determine your model number by looking at the information label on the back of the air purifier The model number will be listed on the label Then call 1 800 ...

Страница 23: ...n temporary program override mode Refer to Override of Auto Mode on pg 12 Confirm that the unit is in Auto Mode The Auto indicator should be lit and a program number should be illuminated See Auto Mode on pg 10 Review program settings to confirm program set points See Reviewing Programs on pg 18 for additional information Check that the proper display is chosen See Display Modes on pg 9 Set the ti...

Страница 24: ...MPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DU RATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PERI...

Страница 25: ...IDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE AIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCI DENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YO...

Страница 26: ... www hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 41959 01 Printed in China and Taiwan M AM 4 TEMP 41959 01_3 30 06 pmd 3 30 06 3 15 PM 26 ...

Отзывы: