What to Expect with Your Installation

Read and Save These Instructions

This product conforms to UL Standard 507.

WARNINGS

CAUTIONS

Know your wiring

If you are unfamiliar 
with wiring, use a 

qualified electrician.

You may need a 
friend to help you.

Check box to see 

fan weight

Assess location

76.2 cm / 

30 in.

from blade tip 
to nearest wall 
or obstruction

2.15 m / 

7 ft.

from bottom 

edge of blade 

to the floor

Select a downrod length

Assess ceiling angle

Must be able to 

secure the fan to 

building structure or 

fan-rated outlet box

1

2

3

Standard Downrod

(included, pre-assembled) 

for ceilings 2.4–3 meters /  

8–10 feet high

Shorter Downrod

(included)

for fans installed close to ceiling

Longer Downrod

(sold separately) 

for ceilings 3 meters / 10 feet or 

higher

Ceiling angles greater 
than 34° will require an 
Angled Mounting Kit. 
See page 4 for details.

w.1 - To reduce the risk of fire, electrical shock, or personal 

injury, mount fan directly from building structure and/or an 
outlet box marked acceptable for fan support of 70 lbs (31.8 kg) 
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or 
servicing your fan, disconnect the power by turning off the 
circuit breakers to the outlet box and associated wall switch 
location. If you cannot lock the circuit breakers in the off 
position, securely fasten a prominent warning device, such as a 
tag, to the service panel.
w.3 - 

To reduce the risk of fire, electrical shock, or motor damage, 

use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade 
brackets when installing the blade brackets, balancing the blades, 
or cleaning the fan. Do not insert foreign objects in between 
rotating fan blades.

c.1 - All wiring must be in accordance with national and local 
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, 

use a qualified electrician. 

c.2 - Use only Hunter replacement parts.

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to part 15 of the FCC 
Rules. These limits are to provide reasonable protection against 
harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and if not 
installed and used in accordance with the instructions may cause 
harmful interference to radio communications.
This product may cause interference to radio equipment and 
should not be installed near maritime safety communications 
equipment, ships at sea, or other critical navigation or 
communications equipment operating between 0.45-30 MHz.
This device complies with Part 18 of the FCC Rules.

Содержание M3571-01

Страница 1: ...It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud...

Страница 2: ...y turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as...

Страница 3: ...0 1326 Tools Needed Ladder Power Drill optional Screwdrivers Pliers Wire Strippers If mounting to a support structure you will also need these tools 36 cm 9 64 in Drill Bit optional 3 M3571 01 06 29 1...

Страница 4: ...LY a Longer Downrod most common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting or Low Profile Mounting to hang the fan from a flat ceili...

Страница 5: ...housing by unscrewing the five screws Discard the shipping ring and the screws Do not discard the hardware bags or mix parts from different bags Make note of the symbol printed on each hardware bag Th...

Страница 6: ...al Support at 1 888 830 1326 Make sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in sup...

Страница 7: ...n 1 Option 2 Option 3 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe Included pre assemble...

Страница 8: ...t stops Downrod continued Tighten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall KEEP The wires can be cut but leave at least 20 cm 8 in extend...

Страница 9: ...inued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fa...

Страница 10: ...reen yellow stripe grounding green yellow stripe green yellow stripe Note To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight...

Страница 11: ...the ceiling to both the white wire from the receiver and the white wire from the fan FROM RECEIVER black blue yellow blue Using the orange wire connectors from the remote control hardware bag Connect...

Страница 12: ...to place so that the screw holes are aligned Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Insert the two canopy screws found in the hardware bag...

Страница 13: ...rews are attached Repeat this step for each blade assembly Install the blade grommets found in the hardware bag in the blades by hand Place each blade between a blade iron and medallion Install three...

Страница 14: ...sing It does not matter which two screw holes you choose Insert the third screw found in the hardware bag into place and tighten all three screws securely Make sure the upper switch housing is securel...

Страница 15: ...upper switch housing Failure to properly secure all three assembly screws could result in the light fixture falling Connect the plugs from the upper and lower switch housings Make sure to line up the...

Страница 16: ...the tabs in the light kit Attach the globe by lifting and twisting counterclockwise until it rests firmly in place Install the included LED bulbs into the sockets When necessary replace with bulbs of...

Страница 17: ...n the battery contacts and also those of the device prior to battery installation The battery should be installed with the positive side up Please contact your local battery recycling center for prope...

Страница 18: ...ming Mode To enable dimming your remote must be set to Dimming Mode To toggle Dimming Mode on or off hold down the Fan Off button while pressing the Light button twice Low Medium High Fan Off Light Yo...

Страница 19: ...the lights will be completely off The Safe Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out To use Safe Exit Safe Exit For c...

Страница 20: ...rcuit breaker then loosen the canopy and check all the connections according to the wiring diagram on pages 10 11 Check the plug connection in the switch housing Remote control of fan is erratic Make...

Отзывы: