Testing controller voltage
Test Wi-Fi on the controller
Test Water Supply
The water could be been shut off to the zone valves. Go to the zone valve and give the
solenoid (where the wires are connected) a ½-turn counterclockwise. If the valves have
water, the sprinklers will come on even without the controller. See the illustration below for
activating the valve solenoid manually:
If the sprinklers turn on by manually twisting the solenoid, follow the next step to check for
proper voltage.
Test Controller Voltage
To confirm proper voltage is getting to the valves using a voltmeter, follow the steps below:
1.
From the
Home
screen, navigate to the
Zone Summary
screen by
pressing
Zones
.
From the Zone Summary screen, touch the zone you wish to view. The
Zone Summary screen shows the status of six zones at a time. To view
the next or previous group of zones, use the
Next
and
Previous
buttons.
The current range of zones that you are viewing is indicated at the top of
the screen.
From the Zone Status screen, you can manually start a zone using the
Run Now
button. When started, the zone will run for the zone’s default
configured run length. This can be overridden by clicking on
Run Time
prior to manually starting the zone. When a zone is running, the
Run Now
Copyright 2020 Hunter Industries. All Rights Reserved.
22
Содержание Hydrawise Ready
Страница 1: ......
Страница 50: ...CONTROLLER SCREENSHOTS Copyright 2020 Hunter Industries All Rights Reserved 50 ...
Страница 58: ...Step 2 Step 3 Copyright 2020 Hunter Industries All Rights Reserved 58 ...
Страница 59: ...Step 4 Copyright 2020 Hunter Industries All Rights Reserved 59 ...
Страница 82: ...Copyright 2020 Hunter Industries All Rights Reserved 82 ...