HC-075-FLOW
(¾")
HC-100-FLOW
(1")
HC-150-FLOW
(1½")
HC-200-FLOW (2")
Inlet/outlet
connection size
¾" NPT body,
male thread
1" NPT body, male
thread
1½" NPT body,
male thread
2" NPT body, male
thread
Meter internal
diameter
3/4"
1"
1.5"
2"
Minimum flow (GPM)
0.22
0.3
0.88
1.98
Maximum
recommended flow
(GPM)
15
30
66
105
Maximum flow rate
(GPM)
21
34
88
132
Dial reading (US gal)
1 pulse per 0.1
U.S. gal
1 pulse per 1 U.S.
gal
1 pulse per 1 U.S.
gal
1 pulse per 1 U.S.
gal
Maximum working
pressure (PSI)
230
230
230
230
Flow Meter - Reading Meter
The Hydrawise flow meters come in a US Gallon reading for domestic and metric reading
called M³ (Meters Cubed 1000 Liters) for international. Conversion rate for metric meters is
3.78 Liters to 1 US Gallon if required.
See example of meter reading below in US gallons:
Fig. 1
X100
8100 Gallons
Fig. 2
X10
814X.XX Gallons
Fig. 3
X1
8142.XX Gallons
Fig. 4
X0.1
8142.4X Gallons
Fig. 5
X0.01
8142.46 Gallons Total