6
winds in the installation area can be entered while the wiring door is
removed. The factory default setting is 5 mph (8 kph). With the wiring
cover removed, a DIP switch is visible allowing other prevailing
average wind speeds to be set, according to the Table 1 (note
that Switch 4 is not used).
If the optional ET Wind sensor is installed, mount
the ET Wind sensor according to its instructions,
and connect the blue and white conductors from
the ET Sensor to the appropriately labeled termi-
nals and secure their screws. Do not reverse the
blue and white wire connections from ET Wind…
connect as shown!
Replace the wiring compartment door and secure
with the screws.
Metal Fence Pole
Steel adapters are supplied for most popular sizes
of galvanized steel fence posts, 2" diameter and
smaller.
Additional materials (not supplied):
2 x 2" galva-
nized or stainless steel U-bolts, 3" long or greater
4 nuts and washers for U-bolts
Bag of concrete
If pole is new construction for specific purpose
of mounting ET Sensor, dig approximately 12" x
12" hole and fill with approximately one 90 lb. bag
of concrete, or place as required by local code.
Insert pole, check with level and straighten, and
brace until concrete is firmly set.
Insert U-bolts around pole through steel pole
adaptors, and through mating holes in ET Sensor
back plane. Add washers, thread nuts onto U-bolt,
and tighten. Do not overtighten.
Route ET Sensor wire to ground surface or burial trench, and run back
to ET Module.
External mounting in outdoor low voltage conduit
(for the above-ground exposed portion of the wire
run) is recommended for protection from the ele-
ments.
Wooden Post
Additional materials (not supplied):
4x4"/100mm
2
pressure-treated, outdoor, direct-burial grade
4x4"/100mm
2
or larger post.
100mm x 6mm dia. x 3,8cm long galvanized or
stainless steel lag bolts and washers
Nut driver for lag bolts
Bag of concrete
Dig approximately 12" x 12"/30cm x 30cm hole (or greater, as
local code dictates) and fill with approximately one bag of concrete.
Insert post, check with level and straighten, and brace until concrete
is firmly set.
Level, mark, and drill pilot holes for 4 lag screws through back of ET
Sensor holes. Insert lag bolts and washers through mounting hole in
backplane of ET Sensor and tighten. Do not overtighten.
Route ET Sensor wire to ground surface or burial trench, and run back
to ET Module.
External mounting in outdoor low voltage conduit (for the above-
ground exposed portion of the wire run) is recommended for protec-
tion from the elements.
Wall or Eave
Additional materials (not supplied): 4 x ¼" dia. x 1.5" (100mm x 6mm
x 40mm) long galvanized or stainless steel lag bolts and washers.
Nut driver for lag bolts.
Level, mark, and drill pilot holes for 4 lag screws through back of ET
Sensor holes. Insert lag bolts and washers through mounting hole in
backplane of ET Sensor and tighten. Do not overtighten.
Route ET Sensor wire to ground surface or burial trench, and run back