SAFETY & PRECAUTIONS

3

READ THE ENTIRE MANUAL BEFORE OPERATING THE FAN

Read and understand this manual before installing or operating a fan unit. Installation, adjustment, repair, or maintenance must 
be performed by qualified personnel.

Follow all safety practices and instructions during the installation, operation, and servicing of the fan. Failure to apply 
these safety practices could result in death or serious injury.

 If you do not understand the instructions, please call our 

Technical Department at 1-844-593-FANS (3267) for guidance.

All fan controls and incoming power should be installed only by qualified technicians familiar with the requirements of the National 
Electrical Code and local codes. Failure to follow these guidelines will void the manufacturer’s warranty. All electrical controls are 
configured at the factory and are ready to use. No user adjustments are available. Follow the included installation instructions 
when installing this device to ensure proper operation. Do not make any changes to any part of the fan without first consulting 
Hunter Industrial Fan. Installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and local codes.

The user is responsible for compliance with all international and National Electrical Code requirements with respect to grounding 
of all equipment. Many of the parts of this unit operate at line voltage. 

DO NOT TOUCH

 any live conductors. Install all covers before 

applying power or starting and stopping the unit. To reduce the risk of electric shock or injury, use this unit only in the manner 
intended by the manufacturer. If you have questions, call our Technical Department at 1-844-593-FANS (3267).
Before servicing or cleaning the unit, switch power off at the service panel and lock the service disconnecting means to prevent 
power from being switched on  
accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning sign, such as a tag, 
to the service panel. At all times, leave the power off at the service panel. To reduce the risk of electric shock or injury, use this 
unit only in the manner intended by the manufacturer. If you have questions, call our Technical Department at 1-844-593-FANS 
(3267).

DAMAGED EQUIPMENT

Do not operate or install any fans or fan accessories that appear to be damaged.

 

Failure to follow this instruction can result in 

death, serious injury, or equipment damage.

SERVICE

If the fan does not operate properly using the procedures in this manual, remove all power to the unit and contact our Technical 
Department for further assistance at 1-844-593-FANS (3267). 

Keep all body parts clear of moving parts at all times. All electrical 

troubleshooting and repair must be done by a qualified technician and meet all applicable codes.

W A R N I N G !

     

Be aware of electric shock hazard, explosion, or arc flash

Содержание ECO 14

Страница 1: ...VEL INSTALLATION Full turnkey installation includes routing all electrical wire and conduit from each fan location to electrical panel terminating electrical connections with NEMA rated receptacles scissor lift rental if necessary mounting all fans and equipment routing all communication cables connecting fans and control if applicable to power supply routing low voltage fire relay cable from each...

Страница 2: ...CY MOUNTING SAFETY ECO 14 4 5 3 9 A 2 4 2 1 A 2 0 1 6 A Downrod length must be specified at time of order OPTIONAL INCLUDED CERTIFICATIONS ETL Intertek certified to ANSI UL 507 and CSA C22 2 No 113 in North America 10 year Non Prorated Warranty Fan I beam mount with pre wired downrod Control panel Install manual Mounting hardware kit Communication Kit Guy wire kit Additional cable lengths Glulam b...

Страница 3: ... equipment Many of the parts of this unit operate at line voltage DO NOT TOUCH any live conductors Install all covers before applying power or starting and stopping the unit To reduce the risk of electric shock or injury use this unit only in the manner intended by the manufacturer If you have questions call our Technical Department at 1 844 593 FANS 3267 Before servicing or cleaning the unit swit...

Страница 4: ...he maximum hanging weight of a 24 fan with a 10 downrod is 232 lbs If there is any uncertainty in the strength of the building structure a professional structural engineer should perform a thorough evaluation of the building prior to purchasing the fans Hunter Industrial Fan provides guidelines for mounting fans however it is the sole responsibility of the building owner and installer to ensure th...

Страница 5: ...NFORMATION ON PLACEMENT AND SPACING If possible avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving airfoils Note a large fan 20 to 24 feet in diameter performs best at 20 to 30 feet above the floor but acceptable performance has been demonstrated as low as 10 feet and as high as 50 feet If the building has a mezzanine fans should be mounted so a pers...

Страница 6: ...ling to the fan s airfoils We recommend fan owners keep airfoils clean by having a maintenance person or skilled trade professional who has experience using a lift wipe the fan airfoils with a rag or sponge using hot water or regular cleaning solutions Please do not use chlorine or any chemicals containing chlorine RETENTION SYSTEM CHECK Each fan is installed with a retention system The retention ...

Страница 7: ...Beam Cl c c urnbuckles GUY WIRE KIT a a 2 S b b 2 Cl c c 4 Bolts Nuts Washers MOUNTING HARDWARE KIT FAN COMPONENTS a 1 Downr b 1 Motor 4 Motor Nu c 1 350 Series Contr d 1 Control Pan e 4 Blad a ECO Installation Manu b HMI installation and user gui MOUNTING HARDWARE KIT GUY WIRE KIT COMMUNICATON KIT INSTALLATION MANUALS ...

Страница 8: ...aisy chained to control up to 5 fans 3 5 LCD Touchscreen Alert Readouts Plug n Play design Standard junction box Simple flush mounting 2 73 69 31 2 00 50 80 3 95 100 31 3 05 77 44 3 55 90 14 0 203 4 places 5 16 2 06 52 26 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL CONTROL ...

Страница 9: ...ctly from screen Most cost effective network controller NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 10 FANS 4 3 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 4 3 TOUCHSCREEN 430 SERIES TOUCHSCREEN CONTROLLER 4 30 109 31 5 88 149 31 UP TO 10 FANS 3 59 91 20 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUN...

Страница 10: ...cheduling grouping and fan naming Fan diagnostics directly from screen NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 30 FANS 7 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 700 TOUCHSCREEN 5 18 131 60 7 69 195 20 4 04 102 70 CONTROL 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Страница 11: ...and BACnet IP IP67 BTL CE FCC CLASS B C PART 15 UL 60950 IC CANADA ROHS AND WEEE COMPLIANT PTCRB AND CTIA OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE ENCLOSURE RATING CERTIFICATIONS 20 TO 70 C 4 TO 158 F 10 95 RH NON CONDENSING 24VAC 125MA 12 24VDC 250MA 12VDC BACNET GATEWAY 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Страница 12: ...802 3AB 802 3X FOR GIGABIT ETHERNET CE CSA EICC UL E200031 ROHS 2 COMPLIANT OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE MAX POWER ENCLOSURE RATING CERTIFICATIONS 40 TO 75 C 40 TO 167 F 10 95 RH NON CONDENSING CLASS 2 POWER SUPPLY 12 48VDC 18 30VAC 50 60HZ BACNET GATEWAY OPTIONS FOR CONTROLS 12 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERF...

Страница 13: ...ELECTRICAL 13 ...

Страница 14: ...Connect a wire from terminal S to SB on the Fire Relay Terminal Strip Connect a wire from terminal C to C on the Fire Relay Terminal Strip Apply 12 40VDC from Fire Panel to Fire Relay Input Relay has a 20mA draw NORMALLY ENERGIZED On the Terminal Strip mounted to the outside of the VFD enclosure a Jumper will be in place on terminals S and C Remove the Jumper from terminals S and C Connect a wire ...

Страница 15: ...MAXIMUM Normally Energized Unenergized Dry Contacts VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure with Fire Relay Fire Panel 10 40VDC VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay Fire Panel Normally Closed 15 ...

Страница 16: ...16 ECO 14 3 14 ...

Отзывы: