17
1. Loosen, but do not remove, the terminal
screws.
Note:
A jumper wire has been provided, connecting the
RC and RH terminals for systems that do not provide both
an RH and RC wire. If you have both an RH and RC wire,
remove this jumper. If you do not have both an RH and RC
wire, leave the jumper in place.
2. Match and connect the wires
from the wall to the terminals as
shown. Wires should be inserted
behind the black terminal shields.
Tighten each screw after the
connection has been made.
(The ends of any extra wires should be wrapped in
electrical tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the
wall to prevent interference.
G RC RH Y W
Jumper